Procedure
:
1) Remove the Valve from the chemical
protective suit by unscrewing the Centre
screw.
2) Once removed, you should have four
parts. From left in the picture below:
Valve body, Rubber gasket, Distribution
house and Centre screw.
3) Service-kit contents:
2
A
B C D
E
F
3
4) Valve body: Carefully remove O-rings
“A” and “B”. Do not scratch the metal
surface! Replace with the new O-rings.
5) Centre screw: Remove O-rings “C” and
“D”. If you use a pair of tweezers, be very
careful not to scratch the metal surface!
A
B
4
C
D
5
7.2.1 Service instructions
Component
Article no
Service-kit for Regulating valve & Passthrough MkII
K72 141 100 (1 pce)
K72 141 101 (10 pcs)
Tools
Torque wrench/screwdriver with Allen key, 5 mm
Not available from Ansell