12
8.2 Performance
PROPERTY
VALUE
Suit ventilation air flow at 7.5 bars @ setting
2 litres/minute
30 litres/minute
100 litres/minute
1.6-2.4 litres/minute
25-35 litres/minute
90-110 litres/minute
Breathing air flow at 5.5 bar
> 310 litres per minute
Work pressure
Maximum
Minimum
10 bars
5.5 bars
Temperature of use
Maximum
Minimum
+70°C
-40°C
Weight (valve only, no belt or hose)
Approx. 200 grams
8.3 Spare part list
DESCRIPTION
ARTICLE NUMBER
Service-kit, 1 pce (includes instructions)
K72 141 100
Service-kit, 10 pcs (includes instructions)
K72 141 101