Safety-2

PN: 10100-00055  Rev. B

Model OSL Series CG

Safety Symbols Used on Equipment and in Manuals

The following safety symbols are used inside or on the equipment near 
operation locations to provide information about safety items and operation 
precautions. Ensure that you clearly understand the meanings of the symbols 
and take the necessary precautions before operating the equipment. Some or all 
of the following five symbols may or may not be used on all Anritsu equipment. 
In addition, there may be other labels attached to products that are not shown 
in the diagrams in this manual.

This indicates a prohibited operation. The prohibited operation is 
indicated symbolically in or near the barred circle.

This indicates a compulsory safety precaution. The required operation 
is indicated symbolically in or near the circle.

This indicates a warning or caution. The contents are indicated 
symbolically in or near the triangle.

This indicates a note. The contents are described in the box.

These indicate that the marked part should be recycled.

Содержание OSL Series

Страница 1: ...LIABILITY FOR CONSEQUENTIAL DAMAGES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL ANRITSU COMPANY OR ITS SUPPLIERS BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL...

Страница 2: ...export this product or any of its manuals please contact Anritsu Company to confirm whether or not these items are export controlled When disposing of export controlled items the products and manuals...

Страница 3: ...he equipment Symbols Used in Manuals Danger This indicates a very dangerous procedure that could result in serious injury or death or loss related to equipment malfunction if not performed properly Wa...

Страница 4: ...e symbols may or may not be used on all Anritsu equipment In addition there may be other labels attached to products that are not shown in the diagrams in this manual This indicates a prohibited opera...

Страница 5: ...Description 1 1 1 3 Recommended Test Equipment 1 2 Chapter 2 Performance Verification 2 1 Introduction 2 1 2 2 Specifications 2 2 2 3 Verification Procedures 2 3 VNA Calibration Procedure 2 4 Return L...

Страница 6: ...Contents 2 PN 10100 00055 Rev B Model OSL Series CG...

Страница 7: ...sists of the following models Table 1 1 OSL Series Precision Open Short Load Calibration Tees Anritsu Part Number Description OSLN50LF N male Precision Open Short Load DC to 4 GHz OSLNF50LF N female P...

Страница 8: ...ical Specification Recommended Manufacturer Model Vector Network Analyzer Frequency 40 MHz to 20 GHz Anritsu Model 37247D or 37347D Calibration Kit Connector Type N Impedance 50 Ohm Termination slidin...

Страница 9: ...e performance of the OSL Series Open Short Load Calibration Tees The tests include Return Loss Verification Open and Short 180 Phase Shift Verification Precision Load DC Resistance Verification The Lo...

Страница 10: ...1 OSL Series Specifications Anritsu Part Number Specification OSLN50LF OSLNF50LF OSLN50 1 OSLNF50 1 OSLN50 OSLNF50 Frequency Range DC to 4 GHz DC to 6 GHz DC to 18 GHz Load DC Resistance 50 0 25 Ohm...

Страница 11: ...s VNA calibration and Return Loss Verification Procedures on page 2 5 Open and Short 180 Phase Shift Verification on page 2 6 Precision Load DC Resistance Verification on page 2 7 Equipment Required A...

Страница 12: ...ess the Utility Menu key b Cal Component Utilities c Install the information from the floppy disk 5 Press the Default Program key to reset the VNA 6 Press the BeginCal key then set the calibration as...

Страница 13: ...DISPLAY MARKERS ON g Readout Marker MARKER TO MAX h The MARKER 1 will display the highest point worst case in return loss in frequency and a negative number in dB for example 43 123 dB at 3 GHz i Reco...

Страница 14: ...0LF and OSLNF50LF upper 170 lower 190 for OSLN50 1 and OSLNF50 1 upper 160 lower 200 for OSLN50 or OSLNF50 display limits ON 2 Connect the SHORT of the DUT Calibration Tee to the adapter on VNA Port 1...

Страница 15: ...sion Load DC Resistance Verification Equipment Required Agilent Model 34401A Multi meter Procedure Use an Ohmmeter to measure the DC resistance between the outer conductor and center conductor of the...

Страница 16: ...2 8 PN 10100 00055 Rev B Model OSL Series CG...

Страница 17: ......

Страница 18: ...Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com Anritsu Prints on Recycled Paper with Vegetable Soybean Oil Ink...

Отзывы: