33
Network Master Pro MT1040A
Method for Adding Measurement Modules
Adding Transport Module (MU10401xA)
1) Confirm that the MT1040A-020 option is installed in the MT1040A
main unit.
2) Choose the bolts matching the added module.
Use the B0741A for the MU10401xA module
For Adding MU10001xA,
MU10002xA (B0740A)
For Adding MU10401xA Module
(B0741A)
Standard Part
(B0731A)
3) Align the transport module horizontally with the MT1040A as shown
below.
MT1040A Main Unit Side
Measurement Modules Side
Align the connectors on the left side.
4) Install the transport module in the correct MT1040A slot as shown below.
400G (QSFP-DD) Module
MU104014A
400G (QSFP-DD) Module
MU104014A
MT1040A Mainframe
Side View after Assembling Modules
Note: Align the four edges when installing the option; the module connector is
easily damaged by misalignment.
5) Secure the module using the B0741A part chosen in step 2.
After installing the module as shown in the figure on the right, check
that there is no gap between the modules.
After attaching the modules
1) Connect the G0419A standard accessory of the MT1040A-020 option
to the MT1040A. The G0418A will not start. Additionally, battery
operation is not possible when two transport modules are installed.
2) Turn on the MT1040A.
Please check whether a new
module is recognized at the
system information.