Anritsu Network Master Pro MT1040A Скачать руководство пользователя страница 33

   

33

Network Master Pro MT1040A

Method for Adding Measurement Modules

Adding Transport Module (MU10401xA)

1)  Confirm that the MT1040A-020 option is installed in the MT1040A 

main unit.

2)  Choose the bolts matching the added module. 

Use the B0741A for the MU10401xA module

For Adding MU10001xA, 

MU10002xA (B0740A)

For Adding MU10401xA Module

(B0741A)

Standard Part 

(B0731A)

    

3)  Align the transport module horizontally with the MT1040A as shown 

below.

MT1040A Main Unit Side

Measurement Modules Side

Align the connectors on the left side.

4)  Install the transport module in the correct MT1040A slot as shown below.

400G (QSFP-DD) Module 

MU104014A
400G (QSFP-DD) Module 

MU104014A
MT1040A Mainframe

Side View after Assembling Modules

Note:  Align the four edges when installing the option; the module connector is 

easily damaged by misalignment.

5)  Secure the module using the B0741A part chosen in step 2. 

After installing the module as shown in the figure on the right, check 

that there is no gap between the modules.

     

 After attaching the modules

1)  Connect the G0419A standard accessory of the MT1040A-020 option 

to the MT1040A. The G0418A will not start. Additionally, battery 

operation is not possible when two transport modules are installed.

2)  Turn on the MT1040A.  

Please check whether a new  

module is recognized at the  

system information.

Содержание Network Master Pro MT1040A

Страница 1: ...Series Network Master Pro MT1040A 400G QSFP DD Multirate Module MU104014A 400G OSFP Multirate Module MU104015A 100G Multirate Module MU104011A MU100011A 10G Multirate Module MU100010A OTDR Module MU10...

Страница 2: ...ecting Polish Type Connector Adapter 14 2 2 3 Selecting Visible Light Source Option 14 2 3 OTDR Module 1310 1550 1625 nm SMF MU100022A 15 2 3 1 Selecting Dynamic Range 15 2 3 2 Selecting Polish Type C...

Страница 3: ...er 400 W 1 The presence of the MT1040A 006 option can be recognized at the top right of the front panel To retrofit it please contact sales representative Without MT1040A 006 With in MT1040A 006 2 One...

Страница 4: ...100G with independent dual port 200G 400G 200G 400G single port Select Optical I F Select the model for choosing the optical module frequency and bit rate from 1 6 Selecting Optical Transceiver for T...

Страница 5: ...odel with the required connector type from 2 3 2 Selecting Polish Type Connector Adapter Page 15 Choose MU100020A Page 13 Wavelength select Choose MU100022A Page 15 Single Model only 2 Wavelength 1310...

Страница 6: ...88 v2 E OAM MU104014A 012 Ethernet up to 25G Dual Channel MU104014A 013 Ethernet 40G Single Channel MU104014A 014 Ethernet 40G Dual Channel MU104014A 015 Ethernet 100G Single Channel MU104014A 016 Eth...

Страница 7: ...VLAN SyncE IEEE 1588 v2 E OAM MU104015A 012 Ethernet up to 25G Dual Channel MU104015A 013 Ethernet 40G Single Channel MU104015A 015 Ethernet 100G Single Channel OTN Errors Alarms Error Performance De...

Страница 8: ...hannel MU104011A 014 Ethernet 40G Dual Channel MU104011A 015 Ethernet 100G Single Channel MU104011A 016 Ethernet 100G Dual Channel OTN Errors Alarms Error Performance Delay APS Test FEC Test O 182 Tes...

Страница 9: ...Dual Channel ODU Multiplexing Addition 4 MU100010A 061 ODU Multiplexing ODU Flex Addition 5 MU100010A 062 ODU Flex CPRI OBSAI CPRI OBSAI L1 Level Bit Rate Frequency deviation Measurement Alarms Error...

Страница 10: ...Generation Tributary Scan MU100011A 001 Up to 10G Single Channel MU100011A 003 Up to 10G Dual Channel MU100011A 053 OTN 40G Single Channel MU100011A 055 OTN 100G Single Channel ODU Multiplexing Additi...

Страница 11: ...P G0322A 1G 2G 4G FC 1310 nm SFP SFP G0323A 1G 2G 4G FC 1550 nm SFP SFP G0315A 10G LR LW 1310 nm SFP SFP G0316A 10G ER EW 1550 nm 40 km SFP SFP G0318A 10G ZR ZW 1550 nm 80 km SFP SFP G0329A 10G LR 131...

Страница 12: ...ed manual Z1821A Utilities in USB Stick USB memory with operation manual remote scripts instruction manual etc J1583A Optical Attenuator 10 dB LC PC to LC PC J1584A RJ45 Cable 3 m J1585A RJ48 to Croco...

Страница 13: ...Connector MU100020A 010 MU100020A 040 MU100020A 011 MU100020A 026 2 1 3 Selecting Visible Light Source Option Breaks in the optical fiber can be detected visually using this light source This option...

Страница 14: ...for the SMF and MMF ports 2 There is no APC polish type for the MMF port As a result this connector adapter polish type is UPC 2 2 3 Selecting Visible Light Source Option Breaks in the optical fiber...

Страница 15: ...3 Selecting Visible Light Source Option Breaks in the optical fiber can be detected visually using this light source This option cannot be added after purchase Model Name Notes MU100022A 002 Visual F...

Страница 16: ...0 1550 nm and the SM port 1650 nm 2 4 3 Selecting Visible Light Source Option Breaks in the optical fiber can be detected visually using this light source This option cannot be added after purchase Mo...

Страница 17: ...reate reports W3810AE MT1000A MU100020A Network Master Pro Operation Manual MT1000A and MU100020A MU100021A MU100022A MU100023A operation manuals 2 5 2 Optical Fiber Conversion Adapters Model Name Not...

Страница 18: ...550 850 1300 nm SMF MMF MU100021A 1310 1550 1625 nm SMF MU100022A 1310 1550 1650 nm SMF MU100023A Video Inspection Probe G0382A G0306B Scratches and dirt on the connector end face are a major cause of...

Страница 19: ...w 4U 4 units screw set Total 4 pcs B0741A Screw 5U 5 units screw set Total 4 pcs B0769A MT1040A Screw Kit Composed of B0730A B0731A B0740A and B0741A New Purchase Common Application Parts Extended War...

Страница 20: ...tended Warranty Service standard 1 year 4 years Model Name MU100011A MU100011A ES210 2 Years Extended Warranty Service standard 1 year 1 year MU100011A ES310 3 Years Extended Warranty Service standard...

Страница 21: ...l Order No Name MX109020A 4 6 7 8 Site Over Remote Access Basic License MX109020A TL001 4 5 Site Over Remote Access 1 Year License MX109020A 001 6 Site Over Remote Access 8 Units MX109020A 002 6 Site...

Страница 22: ...guration requires MTT1040A 020 or not Check your MT1040A has MT1040A 006 or not Please contact sales representative Select Transport Test Options Select the model for choosing the required options fro...

Страница 23: ...nector Select the model with the required connector type from 2 3 2 Selecting Polish Type Connector Adapter Page 15 Single Mode only Choose MU100020A Page 13 Choose MU100022A Page 15 Wavelength select...

Страница 24: ...nel Retrofit MU104014A 314 Ethernet 40G Dual Channel Retrofit MU104014A 315 Ethernet 100G Single Channel Retrofit MU104014A 316 Ethernet 100G Dual Channel Retrofit OTN Errors Alarms Error Performance...

Страница 25: ...can MU104015A 352 OTN up to 10G Dual Channel Retrofit MU104015A 353 OTN 40G Single Channel Retrofit MU104015A 355 OTN 100G Single Channel Retrofit ODU Multiplexing Addition MU104015A 363 ODU Multiplex...

Страница 26: ...y Scan MU104011A 352 OTN up to 10G Dual Channel Retrofit MU104011A 353 OTN 40G Single Channel Retrofit MU104011A 354 OTN 40G Dual Channel Retrofit MU104011A 355 OTN 100G Single Channel Retrofit MU1040...

Страница 27: ...TD Measurement Monitoring using Passthrough MU100010A 371 CPRI OBSAI Up to 5G Dual Channel Retrofit MU100010A 372 CPRI OBSAI 6G to 10G Single Channel Retrofit MU100010A 373 CPRI OBSAI 6G to 10G Dual C...

Страница 28: ...ODU Multiplexing Multi Stage Retrofit ODU Flex Addition 2 5 MU100011A 362 ODU Flex Retrofit CPRI OBSAI CPRI OBSAI L1 Level Bit Rate Frequency deviation Measurement Alarms Errors Detection Unframed BE...

Страница 29: ...lease contact us When adding MT1040A 303 and or MT1040A 311 please either specify one of the following media along with the relevant option or Web download Model Name Z1849A DVD ROM for Retrofit Optio...

Страница 30: ...uad Option 1 MU104014A 400G QSFP DD Multirate Module 2 MU104014A 033 Ethernet 400G Single Channel 2 G0404A QSFP DD 400GBASE LR4 2 Up to 400G Datacom Network Installation and Maintenance Multirate and...

Страница 31: ...er Pro MT1040A Order Sheet When recording different MT1040A configurations on one order sheet describe each MT1040A configuration on one line with the accompanying options under the relevant line Mode...

Страница 32: ...r screws of former module and replace to the next screws Choose the bolts matching the added module Use the B0740A for the OTDR module For Adding MU10001xA MU10002xA B0740A For Adding MU10401xA Module...

Страница 33: ...the correct MT1040A slot as shown below 400G QSFP DD Module MU104014A 400G QSFP DD Module MU104014A MT1040A Mainframe Side View after Assembling Modules Note Align the four edges when installing the...

Страница 34: ...34 Note...

Страница 35: ...35 Note...

Страница 36: ...28 710 United Arab Emirates Anritsu EMEA Ltd Anritsu A S 2106 Singapore Anritsu Pte Ltd 11 Chang Charn Road 04 01 Shriro House Singapore 159640 Phone 65 6282 2400 Fax 65 6282 2533 Vietnam Anritsu Com...

Отзывы: