System
Menu
System Functions
Selects the number of
measurement points
(frequency source
output frequencies)
per measurement trace.
Self
Test
Save/
Recall
Return
To Local
Remote
KEY GROUP
RESET MENU
RESET IS
CONFIGURE
TO KEEP:
CAL DATA
MARKERS
LIMITS
RESET
RESET TO
FACTORY
DEFAULTS
USE THEN
PRESS SELECT
SYSTEM
APPLICATION
SELECT
ROUTINE:
TRACES
AMPLIFIER
TITLES
COLOR
USER SCALING
AUTOZERO
USE THEN
PRESS SELECT
SYSTEM
MENU
DISK UTILITY
SYSTEM SETUP
DATA POINTS
RESET
CONFIGURE:
SOURCE
ANALYZER
PLOTTER
APPLICATIONS
GPIB MODE
USE THEN
PRESS SELECT
FREQUENCY
DATA POINTS
51
101
201
401
USE THEN
PRESS SELECT
Use Data Entry Knob or
Keypad to enter GPIB
address for external
GPIB controlled plotter
(default = 8). Press
CLEAR to exit.
AMPLIFIER
FUNCTION
START POWER
XX.X
MAX POWER
XX.X
INCREASE
POWER UNTIL
LIMITS FAIL
TITLE
FUNCTIONS
USER TITLES
STND TITLES
ENTER TITLES
USE THEN
PRESS SELECT
Exits to GPIB Address
Setup menu
Sets 54XXA GPIB Interface
to PLOTTER mode. Then
exits to plotter setup menu
(Figure 4-5).
ANALYZER
TRACE HOLD:
CH1
CH2
BOTH
AUX CURSOR
READOUT
YES
NO
SMOOTHING
MODE
COUPLED
INDEPENDNT
Freezes data (stops measurement)
for Channel 1 or Channel 2, or both.
Duplicates cursor readout display in
Error Message area of screen display,
if no error messages are displayed.
Smoothing operation set by SMOOTHING
key menus apply to both channels.
See Figure 4-6
Smoothing operation set by SMOOTHING
key menus apply to Channel 1 and/or
Channel 2 independently.
See Figure 4-6
A
B
SET PLOTTER
ADDRESS
8
SET ADDRESS
USING KNOB
OR KEYPAD
A
B
SOURCE
OPERATION
PRESS SELECT
TO
ACTIVATE
SECURE MODE
When in SECURE MODE, all source
frequency information displayed below
graticule is replaced with "SECURE
MODE ACTIVE". All other frequency
information displays (cursor and menu
displays for markers, limits, etc.)
are removed. Refer to text.
Disk Function is inhibited.
GPIB
MODE CHANGE
WARNING:
See note on
Rear Panel
SYSTEM
PLOTTER ONLY
USE THEN
PRESS SELECT
Text Color
R0
G15
B15
CH1 Color
R15
G15
B0
CH2 Color
R15
G0
B0
Grat Color
R0
G15
B0
PRESET
AUTOZERO
MODE
ON
(default)
OFF
USE THEN
PRESS SELECT
Turns Autozero function
on (normal operating
mode
−
see text).
Holds Autozero circuit
correction signal of each
active channel at current
value. This value remains
unchanged until function
returned to "on" (see text).
TRACE
FUNCTIONS
CHANNEL 1
MAX HOLD
MIN HOLD
MAX MIN
CHANNEL 2
MAX HOLD
MIN HOLD
MAX MIN
CLEAR ALL
USE THEN
PRESS SELECT
Resets the 541XXA front panel
control settings to factory
−
selected values. All previously
saved data is erased, unless
specifically saved.
Allows previously saved data
to be retained during system
reset operation (normally
erased). One, two, or all three
types may be retained. Not
active for "SECURE" operating
mode, refer to text.
Sets the initial power level of the frequency
source for the text. The test restarts at this
point each time test is run.
Sets the maximum allowable power level that
will be output by the frequency source during text.
Initiates test using initial power and maximum
power level values currently set. Test terminates
if either Channel 1 or Channel 2 limits are reached,
or maximum power level is reached (see text).
Causes previously defined User Titles to be used
for screen display measurement type titles.
If titles for both channels are currently defined,
both will be displayed.
Reverts to standard screen display measurement
type titles (TRANSMSSN, RETN LOSS, ETC.)
Displays submenu to define User Titles for
Channel 1 and/or Channel 2. Submenu "IDENTIFY"
and "TEST DEVICE" apply to Channel 1 and
Channel 2, respectively.
Sets the color characteristics of the text,
Channel 1 trace, Channel 2 trace, and
graticule for the external VGA monitor
display (Refer to Sections I and II). The
characteristics of the display text, Channel 1
trace, Channel 2 trace, and graticule elements
can each be set seperately.
Each group of three selections sets the
red, green, and blue component for the
associated display element. A value of "0"
designates full
−
off, and "15" designates full on.
The values shown are power
−
on reset default values.
Resets the color display characteristics to the
power
−
on reset default values.
FREQUENCY
SCALING
MULTIPLIER
n
DIVISOR
n
OFFSET
XX.XXXX GHz
SELECT
SCALING
USER
STANDARD
Captures, displays, and holds the maximum
measurement values for Channel 1 during
succesive sweeps."AH" is displays at the
bottom of thescreen for all trace-hold operations.*
Captures, displays, and holds the minimum
measurement values for Channel 1 during
successive sweeps.
Captures, displays, and holds both maximum
and minimum measurementvalues for Channel 1
during successive sweeps.
Same as above, but for Channel 2.
Cancels trace-hold mode operation and
returns to normal measurement mode.
*Example: "AH12" displayed at bottom of
screen when Application Trace Hold is
Active for Channel 1 and Channel 2.
Enter integer value, from
1 to 10 (default value = 1)
Enter integer value, from
1 to 10 (default value = 1)
Enter Offset value,
0 to +/-99.9999 MHz for
Models 54107/09/11,
0 to =/-99.9999 GHz for other
models (default value = 0).
Involves Frequency Scaling
mode (if off). Uses currently
set scaling parameters;
see text.
Cancels Frequency
Scaling mode.
D
D
SYSTEM SETUP
SET CLOCK
KEYCLICK
OFF
ON (low)
ON (high)
MORE
SYSTEM
UTILITIES
DISTANCE IN:
METERS
FEET
CLEAR
NON-VOLATILE
MEMORY
USE THEN
PRESS SELECT
SET CLOCK
CONTROL MENU
DATE
XX/XX/XX
FORMAT
mm/dd
TIME
X.XX pm
FORMAT
12 HR am/pm
24 hour
USE KEYPAD
TO ENTER
DATE AND TIME
Shows current (default) date when
menu first appears. Enter new date,
if required, in 12 or 24 hours format,
as selected below.
Change between day-day/month-month
(dd/mm) or month-month/day-day
(mm/dd) formats.
Always enter time in 24-hour format.
C
C
DISK UTILITY
MORE DIR
RENAME FILE
DELETE FILE
FORMAT DISK
EXIT
DISK UTILITY
USE TO
SELECT FILE
TO RENAME
PRESS SELECT
TO RENAME
OR
CLEAR TO
RETURN TO
UTILITY MENU
DISK UTILITY
USE TO
SELECT FILE
TO DELECT
PRESS SELECT
TO RENAME
OR
CLEAR TO
RETURN TO
UTILITY MENU
ENTER NEW
FILENAME AND
EXTENSIONS
ABCDEFGHIJKL
MNOPQRSTUVWX
YZ0123456789
USE KEYPAD
FOR '.'
DISK UTILITY
MENU
USE THEN
PRESS SELECT
This selection causes additional
directories to appear.
Return to
System Menu
FORMAT DISK
ARE YOU
SURE?
FORMAT THE
FLOPPY DISK
CURRENTLY IN
DISK DRIVE?
NO
YES
PRESS THEN
PRESS SELECT
)LJXUH
6\VWHP)XQFWLRQV.H\*URXS0HQXVRI
I I I FRONT PANEL
SYSTEM FUNCTI ONS
OPERATI ON
KEY GROUP M ENUS
541XXA OM
4-19/4-20
Содержание 540 A Series
Страница 6: ......
Страница 9: ...NOTE ANRITSU Company was formerly known as WILTRON Company LJXUH 0RGHO 1HWZRUN QDO HU ...
Страница 35: ... 6 5 9 DWD RUPDW 51 1 5525 0 66 6 5 5 3 1 211 7256 ...
Страница 59: ... LJXUH DPSOH RI DUG RS 3ULQWRXW FRONT PANEL HARD COPY OPERATION PRINTOUT EXAMPLE 541XXA OM 3 27 ...
Страница 63: ...7DEOH RI RQWHQWV 1752 8 7 21 25 1 7 21 Chapter 4 Front Panel Menus ...
Страница 64: ... LJXUH 6HULHV URQW 3DQHO ...
Страница 169: ...Appendix A 54100A Series Technical Data Sheet ...