background image

- -

 

This machine can be used by children 8 and older and people with physical, sensory or mental 
capabilities or lack of experience and knowledge if they have been given supervision or 
instruction concerning use safely and understand the dangers supone.Los children should not 
play máquina.La cleaning and maintenance of the machine must always be performed by 
qualified personnel. 

Attention! If the machine or the power cord is damaged, they must be repaired by the 
manufacturer, its service agent or a person qualified before continuing use. 

Do not dispose of this machine as if generic junk, use separate collection facilities and 
licensed in your area for proper treatment. Contact local authorities for information on 
the collection points available. 

 Before installation, you should carefully read this manual and heed the warnings and 

safety instructions in this manual. 

The manufacturer is not responsible or liable to take responsibility for personal injury, damage 
to the pump and yield losses in the machine caused by violation of safety precautions in this 
manual. 

1.

 

Applications

It is applicable to domestic water supply, equipment support, pressurization pipes, irrigation and 
fumigation of gardens, irrigation of vegetable greenhouses, breeding, industrial and mining 
supply and drainage water business buildings, high-rise, central air conditioning circulation 
system and central heating. etc.Transferencia clean water and other non-corrosive liquids with 
low viscosity; invalid transport of flammable liquids, explosives, and gasified liquids containing 
solid particles or fibers. The pH liquid must be within 6.5-8.5. 

Observation: 

This pump could become a automatic water pump, which is configured through an external 
automatic plant which comprises a pressure switch, a pressure tank, etc. The characteristics of 
the function of automatic pump are as follows: when the power is on, open the tap and the 
pump will start automatically; When the tap is closed, the pump stops automatically. If a water 
tower along used with automatic pump, connect to the upper limit switch and the pump start or 
stop working with the water level in the water tower automatically. 

2.

 

Technical data

Model: BE1300P 

Motor power: 1300W 
Max flow: 8

3

 L / m 

Output max height: 48 m. 
Start pressure: 1.8 bar 
Off pressure: 3.2 bar 
Max suction height 8 m 
Clase Insulation IPX4 
Clase protection F 
Max working temperature: + 40

 

Содержание BE1300P

Страница 1: ...Instructions User Manual WATER PUMP BE1300P Millasur SL Rua Eduardo Pondal No 23 Pol Ind Sig eiro 15688 Oroso A Coruna 981 696 465 www millasur com EN...

Страница 2: ...anual with you when you go to work with the machine The contents are correct at the time of printing the right to make changes at any time without affecting our legal responsibilities are reserved Thi...

Страница 3: ...NTS 1 Applications 2 Technical data 3 Safety Precautions 4 Identification of parts 5 Installation 6 Start up and maintenance 7 Troubleshooting 8 Disposal and recycling machine 9 Warranty conditions 10...

Страница 4: ...applicable to domestic water supply equipment support pressurization pipes irrigation and fumigation of gardens irrigation of vegetable greenhouses breeding industrial and mining supply and drainage...

Страница 5: ...pump and the pump is immersed in water 5 Keep the pump in a ventilated area 6 If the ambient temperature is less than 4 or if the pump is not used for a long time drain the liquid from the pipe syste...

Страница 6: ...competent in handling the m quina La installation and operation must be in accordance with local regulations and operating criteria reconocidos Instale the pipes correctly according to requirements t...

Страница 7: ...meter of the inlet tube should be less according to the water inlet to avoid excessive loss of water that influence the performance of the outlet 5 Pay attention to the fall of the water level during...

Страница 8: ...future 2 If not then water having started for more than 5 minutes with full water is discharged turn off the electric pump refill water or check whether the inlet pipe is leaking 3 If frost damage an...

Страница 9: ...d Replace winding send maintenance point for repair Line pressure above the set pressure of the pressure switch automatic pump Increase pressure cutting power pressure switch ie turn the screw nut var...

Страница 10: ...pe of bearing The impeller is jammed Remove debris and dirt Delivery head inappropriate and excessive Set to the range shown on the nameplate before use The switch does not work or pressure starts sto...

Страница 11: ...cases correspond if it is well accompanied by their respective machine purchase invoice and be managed through a Anova authorized center ATTENTION TO ENSURE MAXIMUM PERFORMANCE AND SAFETY READ THE IN...

Страница 12: ...urer on it the identified machine that complies document with the relevant requirements and basic safety and health of the directives EC This statement validates the product to display the CE symbol I...