3.Description of the ArcPower 16x6

 

  

 

 

 

 

LED output zones (RGB operation)

 

 

 

 

 

LED output zones (RGBW operation)

    

    

        DMX Input,Output 

 

 

    

     LED module Input

 

 

   RJ45 socket    

 

 

 

 

RJ45 socket 

 

      Front view of the socket: 

 

 

 

     Front view of the socket:

4.Installation

4.1.Connection to the mains:

The ArcPower 16x6 is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz 

AC power source from 100-40 Volts.

Carefully prepare the end of the the supply cord and fit a suitable plug.A 3-prong grounding-type plug must be 

installed following the manufacturer´s instructions.The earth has to be connected!

1

 - Control board

2

 - LED output zones

3

 - DMX Input

4

 - DMX Output

5

 - Fuse holder

6

 - Power cord

Pin 1:

 Not connected 

Pin 5:

 +5V

Pin 2: 

Not connected 

Pin 6: 

Data +

Pin 3:

 Not connected 

Pin 7: 

Data -

Pin 4:

 Not connected 

Pin 8: 

GND

Pin 1:

 Red LED + 

Pin 5: 

Red LED -

Pin 2: 

Green LED + 

Pin 6: 

Green LED -

Pin 3: 

Blue LED + 

Pin 7: 

Blue  LED -

Pin 4: 

White LED + 

Pin 8: 

White LED -

Содержание ArcPower 16x6

Страница 1: ...Version 1 1...

Страница 2: ...DMX operation 6 5 1 Single ArcPower 16x6 installation 6 5 2 Multiple ArcPower 16x6 installation 7 6 ArcPower 16x6 Control menu map 8 7 ArcPower 16x6 DMX protocol version 1 1 9 8 Control board 15 8 1...

Страница 3: ...airs and servicing must be carried out by a qualified employee Do not connect this unit to a dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has to...

Страница 4: ...C power source from 100 240 Volts Carefully prepare the end of the the supply cord and fit a suitable plug A 3 prong grounding type plug must be installed following the manufacturer s instructions The...

Страница 5: ...are four mounting holes of a diameter 5 mm in housing of the driver Ensure that instalation place is enough ventilated 4 3 Conection cables 1 The adapter cable RJ45 XLR connects the ArcPower 16x6 to...

Страница 6: ...see chapter Control board 6 Run internal calibration of the fixture menu path SPEC CALi COMP Warning Accidental connection DMX 512 Input Output to non DMX 512 device e g Ethernet network Hub can dama...

Страница 7: ...ArcPower 16x6 until all fixtures are connected In this way up to 32 fixtures can be chained together At the last ArcPower 16x6 the data link has to be terminated with a terminator A termination plug i...

Страница 8: ...F tim 0 255 S tim 0 255 COPY P End 1 60 MAn C rEd 1 0 255 GrE 1 0 255 bLu 1 0 255 Stro 0 255 dimr 0 255 tESt St AL Auto OFF tESt PrG 5 PLAY EPG 1 SPEC PrG 5 VErS tEmP CALi rEd 1 0 255 bL 16 0 255 Stor...

Страница 9: ...rtional 11 11 0 255 Green LED 4 Green LED saturation control 0 100 proportional 12 12 0 255 Blue LED 4 Blue LED saturation control 0 100 proportional ZONE 5 13 13 0 255 Red LED 5 Red LED saturation co...

Страница 10: ...reen LED 12 Green LED saturation control 0 100 proportional 36 36 0 255 Blue LED 12 Blue LED saturation control 0 100 proportional ZONE 13 37 37 0 255 Red LED 13 Red LED saturation control 0 100 propo...

Страница 11: ...9 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open step step pro...

Страница 12: ...255 Blue LED 4 Blue LED saturation control 0 100 proportional 1 1 0 255 White LED 4 Blue LED saturation control 0 100 proportional ZONE 6 16 16 0 255 Red LED 6 Red LED saturation control 0 100 proport...

Страница 13: ...5 Blue LED 12 Blue LED saturation control 0 100 proportional 12 12 0 255 White LED 12 Blue LED saturation control 0 100 proportional ZONE 14 40 40 0 255 Red LED 14 Red LED saturation control 0 100 pro...

Страница 14: ...9 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open step step pro...

Страница 15: ...ll start to flash frequently 3 Use the UP and Down buttons to select the desired address 4 Confirm by pressing ENTER After having addressed ArcPower 16x6 you may now start operating ArcPower 16x6 via...

Страница 16: ...5 77 2 0 4 55 5 110 20 2 165 45 4 220 80 7 5 2 5 60 6 115 22 170 48 2 225 84 4 10 10 65 7 120 24 175 51 230 88 2 15 22 5 70 8 2 125 26 180 54 235 92 20 40 75 9 4 130 28 2 185 57 240 96 25 62 5 80 10 7...

Страница 17: ...FF ArcPower 16x6 will use maximum value 255 of satura tion for red green and blue channels CALi LED intensity calibration The menu allows you to adjust the max light intensity of individual LEDs colou...

Страница 18: ...der on your hard disk and download the software to it 3 Unpack the program from the archives Program file has name DSU_name of corresponding fixture_SoftwareID SoftwareID describes the versions of fix...

Страница 19: ...s RGBW operation LED zones 12 Max load per zone 8 x 1W LED Total max load 12x8 LEDs Maximum total cable length between one zone of the Arcpower 16x6 and connected LED modules 80 metres at max load DMX...

Страница 20: ...e fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower 16x6 with a fitting screwdriver from the housing anti clockwise 3 Remove the old fuse from the fuse holder 4 Install...

Страница 21: ...21...

Отзывы: