background image

17

Order Mode 

- the menu allows to select a method how LED modules will be assigned to the Artnet Universe. 

 

Order Compact

 - All LED modules will be assigned to the Universe at the first LED output. After filling 

this Universe, the rest of LED modules will be assigned to the Universe at the LED output 2. 

 

Order Universe

 - LED modules output will be assigned to different Universes. LED modules on the 

first LED output to the Universe set at this LED output. LED modules on the second LED output to the Universe 

set at the second LED output etc.

Store Config

 

- select this function to save all changes that have been done in the menu "Dots" .

Test Dots 

- use this menu item to browse throw the list of sorted LED modules.The ID of corresponding dot is 

shown under the dot number. Displayed LED module blinks in white. 

Update Dots

 - allows update of the connected LED modules after standard software updating of the ArcPixel 

Power-CE (item “Software Update” in the menu "Special Setting").

Note: The update via the menu "Software Update" has to be realized before running the "Update Dots" 

procedure 

7.4 Personality

Use this menu to modify the ArcPixel Power-CE operating behavior.

ArtNet Universe 

- use the menu item to assign ArtNet universe to desired LED output.

Uni.1 - ArtNet universe for LED output 1

:

Uni.4 - ArtNet universe for LED output 4

ArtNet is a proprietary protocol for transmitting DMX512 (with RDM) over UDP/IP. Up to sixteen DMX512 

universes can be accessed through one IP subnet. The Universe is a single DMX 512 frame of 512 channels.

DMX Input

 - this menu allows you to choose desired DMX data input:

 

Artnet

 - if this input is selected (RJ45), all LED outputs (1-4) are active.

 

Wired DMX

 - if this input is selected (3-pin XLR), only LED outputs 1-3 are active.

Display Settings

 - this menu allows you to change the display settings.

Display Off Timer

 - if this item is on the display will be swiched off 2 minutes after last pressing any 

button on the control panel. 

Display Lightness

 - select this menu item to adjust the display intensity (0-100%). 

           Display Contrast

- select this menu item to adjust contrast of the display (0-100%).

Skip Cfg Mismatch

 - If this function regards behaviour of the fixture if some dots have been replaced (e.g. 

due to faulty dots).

 

No: after switching the fixture on, the channel with the new dots will be displayed and dots check 

 

procedure will stop.You have to manually assigned new dots.

 

Yes: after switching the fixture on, the dots checking procedure will run and error messages 

 

regards replaced dots will apear (in case that some problem occured). Fixture menu is accessible.

Default setting 

- select this option to set fixture personalities to the default (factory) values.

7.5 Test

Single Dots

 - the LED modules blink one by one starting from DMX address 1 (universe 1) in the colour order 

red, green, blue and white.

All Dots

 - all connected LED modules blink together in the colour order red, green, blue and white..

Before both test sequences, the "Search Dots" and "Sort Dots" procedures from the menu "Dots" have tu be 

made. 

7.6 Special settings

Software Update

 

- using this function you can update software in the fixture via PC and USB (or serial port).

The following are required in order to update software:

 

- PC running Windows 95/98/2000/XP/7/8 or Linux

 

- DMX Software Uploader 

 

- Flash cable RS232/DMX S/N.13050624 (if you want to use a serial port of PC)

Содержание ArcPixel Power CE

Страница 1: ...Version 1 6...

Страница 2: ...l Power CE 6 4 3 Connecting ArcPixes 6 4 4 Connecting ArcDots 9 5 ArcPix Power DMX protocols 11 6 Control menu map 14 7 Control menu 15 7 1 DMX Addr Fixture addressing 15 7 2 Info Fixture information...

Страница 3: ...y ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers t...

Страница 4: ...don d alimentation du pi tinement ou pincement particuli rement au niveau des fiches des prises et le point o ils sortent de l appareil Confiez toute r paration un personnel qualifi Une r paration est...

Страница 5: ...risk of electric shock do not perform any servicing other than that con tained in the operating instructions unless you are qualified to do so 4 1 Connection to the mains The ArcPixel Power CE is equ...

Страница 6: ...and the last ArcPix must not exceed 100 metres For larger installation the ArcPixel Power CE should be connected to the Robe Media Server which allows automatic pixel mapping and full control of the A...

Страница 7: ...er Set another needed items in the ArcPixel Power CE menu Note Never connect disconnect LED modules when the ArcPixelPower CE is under voltage Every ArcPix line has to be terminated with the terminati...

Страница 8: ...300 modules per fixture Every ArcPix line has to be terminated with the termination box ArcPix The Robe Media Server allows to choose two modes of ArcPixes connection Fixed wiring mode and Picture mo...

Страница 9: ...h ArcDots line 3 Connect the ArcPixel Power CE to mains 4 Run procedures Search Dots and Sort Dots from the menu Dots 5 Save adjusted values with the option Store Config 6 Disconnect the ArcPixel Powe...

Страница 10: ...aining three UARTs can be used for LED outputs only LED output load is the same as in a case of the control by Artnet max 35 LED modules per LED output max 100 modules per ArcPixel Power CE Every ArcD...

Страница 11: ...saturation control 0 100 proportional 6 7 0 255 Blue Blue LED saturation control 0 100 proportional 8 0 255 White White LED saturation control 0 100 proportional ArcDot 3 ArcSource Outdoor 4MC Pixel...

Страница 12: ...on control 0 100 proportional ArcPix 3 7 0 255 Red Red LED saturation control 0 100 proportional 8 0 255 Green Green LED saturation control 0 100 proportional 9 0 255 Blue Blue LED saturation control...

Страница 13: ...trobe Closed proportional proportional step step ArcDotFlash 2 2 0 127 128 191 192 254 255 Light Intensity Intensity 0 100 Synchronic strobe from slow to fast Random strobe Closed proportional proport...

Страница 14: ...New Dots Unknown Dots Dots Search Dots Sort Dots Auto Sort Manual Sort Restore Last Fade Time Off 0 1s 25 5s Dots Curve D Curve 0 255 RGBW 4ch Mode On Off Order Mode Order Compact Order Universe Stor...

Страница 15: ...e address The following items IP Adr 1 IP Adr 2 IP Adr 3 IP Adr 4 allow to set each part number of the address After setting desired IP address confirm the item Set Address to save this address Networ...

Страница 16: ...ress the ENTER again selected item will start to blink fast and you can set desired values using the UP and DOWN button After automatic or manual sorting do not forget to save changes by means of the...

Страница 17: ...desired DMX data input Artnet if this input is selected RJ45 all LED outputs 1 4 are active Wired DMX if this input is selected 3 pin XLR only LED outputs 1 3 are active Display Settings this menu al...

Страница 18: ...oftware Update item 4 Press the ENTER button 5 Use the UP and DOWN buttons to select Yes option 6 Press the ENTER button Note If you do not want to continue in the software update you have to switch o...

Страница 19: ...atch 1 Press the ENTER to enter menu New Dot and use the UP and DOWN to browse items Sel 1 Sel 2 appropriate dot lights in green pictures 1 2 2 Select the dot 2 and press the ENTER to enter menu Miss...

Страница 20: ...r dot 1 picture 5 4 Press the ENTER to go back to the menu New Dot and using items Sel 1 Sel 2 you can see incorporated dots picture 6 7 4 5 6 7 5 Select the item Check channel press the ENTER and aft...

Страница 21: ...nu New Dot and select dot 9 picture 13 and press the ENTER to enter the menu Miss Dot The Dot 9 starts flashing in green 11 12 13 8 By means of items Sel 1 Sel 2 Sel 3 select the following colour comb...

Страница 22: ...e the message Store will appear Select option Yes if you wish to save the dot changes 9 ArcPixel Power Web manager The ArcPixel Power includes built in web interface allowing quick overview of its set...

Страница 23: ...23 Tab DOTS Tab SETTINGS Tab TOOLS...

Страница 24: ...ArcPix CE or 100 x ArcDot CE ArcSource Outdoor 4MC Pixel CE ArcDotFlash CE Maximum cable length between output of the ArcPixel Power CE and the last connected LED module ArcPix CE 100 m 100 ArcPixes p...

Страница 25: ...N 1305 2023 Connection cable 2m P N 1305 2024 Connection cable 4m P N 1006 2330 Active Terminator for ArcDot P N 1006 2331 Passive Terminator for ArcDot P N 1305 1703 Ferrite GTFC 16 8 16 for ArcDot...

Страница 26: ...26...

Отзывы: