animeo
KNX 4 DC/E MOTOR CONTROLLER. REF. 5052675-B -
10/16
GB
A
MOUNTING
[1]
Choose the optimal location: flat and large surface
[2]
Mount the KNX 4 DC/E Motor Controller
[3]
Connect power supply and wiring to the
Motor Controller
B
WIRING
[1]
Wiring diagram
[2]
Check the correct running directions of the
end product
UP: the end product goes up ( C +
)
STOP: the end product stops ( C +
+
)
DOWN: the end product goes down ( C +
)
n
To close window press UP,
to open window press DOWN
m
Preset functional mode is DCE!
Max. running distance: 35 cm.
[3]
Possible switches
1.
Inteo Centralis IB, Ref. 1810138
2.
Double push button
C
CONFIGURATION
[1]
Reset / Prog button
With this button, you can access the basic configu-
ration of the Motor Controller.
The „US“ LED is steadily blinking when the mains (230 V)
and the KNX bus power are actively connected to the
device. The device is ready for operation when the „US“
LED is blinking. The Reset / Prog button can be used when
the device is in default condition and is not programmed
by the ETS Software.
[2]
Mode selection DC or DCE
m
Default mode is DCE!
Type of motors which can be controlled are DC or DCE
(if a LW25-E83 motor is used; identifiable at 3 wires).
1.
To toggle between modes, press shortly the
Reset/Prog button.
m
Using an inadmissible functional mode can
damage the motors! The mode is specified for
all 4 motor outputs!
[3]
Selection of switch ergonomic
The different ergonomics are described in the user
manual. Local push button ergonomics and the type
of end products to be preselected:
• Screen mode (SCR)
• Venetian blind, European mode
• Venetian blind, US mode
The default mode is: venetian blind, US mode.
1.
To toggle between modes, press shortly the
Reset/Prog button. Repeat until the LED, accord-
ing to the desired configuration, lights up.
[4]
Factory RESET
[5]
Learn running and tilting times/length
1.
Press immediately when lower end limit is
reached
2.
Maintain stop for duration of tilting
[6]
Symbols: actions
1.
Up
2.
Stop
[7]
Symbols: end product status
1.
Up
2.
High position
3.
Down
4.
Low position
m
If you do not use Somfy motors please follow
the additional information in our detailed
installation guide (www.somfy.com)
Connection to ...
Cables
Twisted pairs
Max. distance
Motors
Min.: 3 x 0.6 mm/22 AWG
Max.: 3 x 2.5 mm
2
/14 AWG
-
20 m
Switches
Min.: 3 x 0.6 mm/22 AWG
Max.: 3 x 2.5 mm
2
/14 AWG
Recommended
100 m
Group control
Min.: 3 x 0.6 mm/22 AWG
Max.: 3 x 1.5 mm
2
/16 AWG
Recommended
50 m
KNX bus
2 x 0.8 mm/20 AWG
Required, following KNX
topology guidelines
220 - 240 V AC
Min.: 3 x 1.5 mm
2
/16 AWG
Max.: 3 x 2.5 mm
2
/14 AWG
-
CABLE