![Anilam 5000M CNC Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/anilam/5000m-cnc/5000m-cnc_manual_2943806017.webp)
CNC Motion Setup/Testing Utility
P/N 70000510B
14
All rights reserved. Subject to change without notice.
31-January-05
Table 4, Table of Fault LED Conditions (5 LEDs)
Input or Fault
Condition
RUN
LED
HS/ECB
LED
LS/ECB
LED
OVER VOLT
LED
OVER TEMP
LED
FAULT
OUTPUT
NORMAL
OPERATION
ON
OFF OFF OFF
OFF GROUND
LIMIT + (ON)
ON
OFF OFF OFF
OFF GROUND
LIMIT – (ON)
ON
OFF OFF OFF
OFF GROUND
CLAMP (ON)
OFF
OFF
OFF
OFF
OFF
GROUND
RESET (ON)
OFF
OFF
OFF
OFF
OFF
PULL-UP
EXT. FAULT
OFF
OFF
OFF
OFF
OFF
PULL-UP
UNDER VOLTAGE
(+15V)
OFF OFF OFF
OFF
OFF
PULL-UP
HS/ECB (LATCHED)
OFF
ON
OFF OFF
OFF
PULL-UP
LS/ECB (LATCHED)
OFF
OFF
ON
OFF OFF
PULL-UP
OVER VOLTAGE B+
(LATCHED)
OFF OFF OFF
ON
OFF
PULL-UP
OVER TEMP
(LATCHED)
OFF OFF OFF
OFF
ON PULL-UP
For LED fault conditions 1 LED servo amplifiers, see
Figure 7, ANILAM
Servo Amplifier (1 LED), P/N 33000123
or
Table 5
.
Table 5, Table of Fault LED Conditions (1 LED)
Green Red Condition
ON OFF
RUN
ON
2 FLASHES
+/– LIMITS
OFF OFF
AMPLIFIER
INHIBIT
OFF ON RESET
OFF
1 FLASH
OVER TEMPERATURE
OFF
2 FLASHES
OVER VOLTAGE
OFF 3
FLASHES
LS/ECB
OFF 4
FLASHES
HS/ECB