FEET TO METER AND METER TO FEET SWAP 

You have the possibility to buy another focus engraved ring in meter or in feet for your Optimo Ultra Compact . The swap of the focus 

scale from one system to the other must be done with cautious in a clean environment to prevent dust or particles pollution inside the 

lens.  If  your  focus  ring  needs  to  be  replaced  please  contact  your  local  reseller  or  our  service  team  at 

[email protected]

 providing the serial number of the lens. 

 

Parts numbers into brackets are referring to the next pages:

 

 

CAUTION:

 

After swapping the scale, please do always check the focus ring functioning. If you notice a mechanical play on the focus 

ring, tighten more the three screws (1) uniformly. If the focus torque is stiff or uneven, release and tighten more uniformly the three 

screws (1).  

 

TIP:

 To help re-installing the focus scale, go to the infinity focus end-stop and put a pencil mark on the front engraved ring (5) in front 

of the infinity position. When installing the focus ring, align the infinity engraving with the mark made. After installing the focus ring, 

check if the marks are correctly aligned by using a collimator, projector or camera. Proceed to a final accurate adjustment if necessary. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 FEET 

 METER 

Содержание OPTIMO ULTRA COMPACT

Страница 1: ...User manual OPTIMO ULTRA COMPACT User manual V1 1 Ref 66070209AA...

Страница 2: ...hout notice This document is the full and sole property of THALES LAS FRANCE ANG NIEUX division Any reproduction rights of reproduction translation modification publication on material or digital medi...

Страница 3: ...PL mount it is the perfect companion for your digital camera Optimo Ultra compact has support Cooke i and is ARRI LDS2 ready This user manual describes the different configurations and uses of your le...

Страница 4: ...2 2 Technical information 2 3 General view and installation 2 4 Spare parts and optional accessories 2 5 Electronics specifications 2 6 Ajustements 2 7 Maintenance recommendations 2 8 Outline drawing...

Страница 5: ...Repairs must only be carried out by authorized Ang nieux Service Centers WARNINGS Handle any lens with care Do not expose lens to water or moisture Do not subject the lens to severe shocks Never inse...

Страница 6: ...Condensation on the optical components may have a visible effect on the output images To prevent condensation store the lens in a dry area If the lens is in a humid area dry it and store it a plastic...

Страница 7: ...roken item please contact our service team at angenieuxservice fr thalesgroup com Set of 9x color shims for back focus adjustment see section 6 Optimo Ultra Compact Box Levers x2 Intermediate lens bra...

Страница 8: ...2 opposite scales 2 opposite scales Angular rotation of iris ring 71 4 Iris gear drive 126 teeth pitch 32 Zoom scales 2 opposite scales Angular rotation of zoom ring 150 Zoom gear drive 126 teeth pitc...

Страница 9: ...a standard installation on camera please proceed as below Remove the rear cap 11 and make sure the rear filter 13 is clean If not please refer to maintenance section 7 Make sure the Optimo Ultra Compa...

Страница 10: ...66723BA 17 Deco red ring 66066352AA 18 Zoom iris index ring 66066722AA Flange shim set of 9 shims see size detail in section 6 0321060 Screws for lens support including LEMO connector holder x2 with t...

Страница 11: ...4 pins on PL mount 9 42 V About 50 mA 12V External connector LEMO 4 pins connector EGB00304CLL 9 42 V About 50 mA 12V If you are facing communication problems between the camera and the lens If the le...

Страница 12: ...A Set of flat spanners for collet nuts Special spanner REPLACING THE MOUNT Please refer to the next page figure for the numbers into brackets Place the Optimo Ultra Compact on the front cap Unscrew th...

Страница 13: ...ease keep the rear filter 1 in place and be sure it is well fitted when doing the back focus adjustment Unscrew the PL retainer 5 anticlockwise Remove the PL sub assembly 1 2 3 4 and 5 Unscrew the scr...

Страница 14: ...e referring to the next pages CAUTION After swapping the scale please do always check the focus ring functioning If you notice a mechanical play on the focus ring tighten more the three screws 1 unifo...

Страница 15: ...e 120 screws 1 holding the engraved focus ring 2 Pull out the engraved focus ring 2 Replace the new engraved focus ring 2 for feet or meter use and put the three screws 1 in contact Re connect the con...

Страница 16: ...g it If you used an Optimo Ultra Compact lens frequently or in extreme conditions make sure the mechanisms works properly If necessary clean and lubricate the mechanism It is highly recommended to use...

Страница 17: ...17 8 Outline drawings...

Страница 18: ...11 5 2 11 2 10 5 2 10 2 9 5 2 9 2 9 2 8 5 2 8 2 7 5 2 7 2 6 5 2 6 2 6 2 5 5 2 5 2 4 5 2 4 2 3 5 2 3 2 3 2 2 5 2 2 2 1 5 2 1 2 0 5 2 0 2 Engraving FEET meter engraving infinity 40 20 20 15 10 10 8 6 6...

Отзывы: