FEET TO METER AND METER TO FEET SWAP
You have the possibility to buy another focus engraved ring in meter or in feet for your Optimo Ultra Compact . The swap of the focus
scale from one system to the other must be done with cautious in a clean environment to prevent dust or particles pollution inside the
lens. If your focus ring needs to be replaced please contact your local reseller or our service team at
providing the serial number of the lens.
Parts numbers into brackets are referring to the next pages:
CAUTION:
After swapping the scale, please do always check the focus ring functioning. If you notice a mechanical play on the focus
ring, tighten more the three screws (1) uniformly. If the focus torque is stiff or uneven, release and tighten more uniformly the three
screws (1).
TIP:
To help re-installing the focus scale, go to the infinity focus end-stop and put a pencil mark on the front engraved ring (5) in front
of the infinity position. When installing the focus ring, align the infinity engraving with the mark made. After installing the focus ring,
check if the marks are correctly aligned by using a collimator, projector or camera. Proceed to a final accurate adjustment if necessary.