IT
GB
DE
FR
ES
C13062
111.
fm
- 23 -
English
3 - Undo the screws
(E)
to remove the lid
(F)
.
4 - Undo the screw
(G)
.
5 - Position the bracket
(H)
so that it is touching the
microswitch
(L)
.
6 - Tighten the screw
(G)
.
7 - Fit the lid
(F)
and secure it with the screw
(E)
.
8 - Replace the control panel
(D)
and the knob
(B)
on completion of the operation.
9 - Raise and lower the well to check that the set-
ting is correct (the well must rest firmly on the
fixed part of the appliance).
10 - Switch on the appliance (see page 9) and
check that it operates correctly (the tempera-
ture light must be on).
To carry out this operation, proceed as follows.
1 - Fit the spanner
(A)
onto the hexagon
(B)
.
2 - Keep a firm grip on the spanner
(A)
and undo
the locking screws
(C)
.
3 - Turn the spanner
(A)
clockwise to load the
spring or anti-clockwise to release it.
4 - Once the correct balance is obtained, screw in
the screws
(C)
without tightening them fully.
5 - Use the spanner
(A)
to turn the shaft until it is
located in one of the seats provided.
6 - Fully tighten the screws
(C)
.
ADJUSTING THE LID COUNTER-BALANCING
IDM-39616002400.tif
E
F
L
H
G
IDM-39615401800.tif
B
A
C
IDM-39615401800.tif
B
A
C