background image

CLEANING AND MAINTENANCE 

 

6  

         L20-352-UK Rev.1 08/12

 

 

 

 
Thermostat Calibration Check  

NOTICE 

Thermostat calibration requires that the temperature of the appliance be raised above 

boiling. If you have water in the tank you will need to drain it, dry it and fill it with 

shortening/oil. Follow the filling instructions in this manual. 

 

 
To check the calibration of your appliance, refer to the following procedure. 

 

a. 

Remove the basket screen from the tank. 

 

b. 

Place the tip of a digital thermometer probe into the shortening/oil approximately one inch 
above the temperature sensor. 

 

c. 

Perform the appliance startup as described in this manual, set the thermostat to 325°F 
(163 °C) and allow the shortening/oil to come up to temperature. Watch the thermometer 
closely as the temperature rises. 

 

d. 

If the shortening/oil temperature reaches 350°F (177 °C) and the burners do not turn off, 
turn the thermostat down. Keep lowering the thermostat setting until the burners turn off. 

CAUTION 

If the burners do not shut off at the LOWEST thermostat setting, the thermostat may be 

defective. Contact your local service company.

 

 

e. 

Let the appliance cycle 4 to 6 times before checking the temperature. Compare the 
thermometer temperature against the thermostat setting. If the values are more than 5°F 
(3 °C) apart, calibrate the thermostat using procedure in this manual. 

 

Thermostat Calibration 

For Gas Thermostats refer to the following procedure: 
 

a. 

Remove the basket screen from the tank and place the tip of a digital thermometer into the 
shortening approximately one inch above the temperature sensor. 

 
b. 

Perform the appliance startup as described in this manual, set the thermostat to 325°F (163 °C) 
and allow the shortening/oil to come up to temperature; let the appliance cycle 4-6 times to 
insure that the oil temperature has stabilized. Compare the thermostat setting of 325°F (163 °C) 
to the digital thermometer reading. 

 

c. 

Remove the thermostat dial by pulling the knob straight out. DO NOT rotate the dial. 

 

d. 

Holding the outside of the shaft so that it does not move, scrape away the sealing compound in 
the center of the shaft with a small flat blade screwdriver. 

 

e. 

Turn the adjustment screw clockwise to lower the thermostat’s temperature setting or counter- 
clockwise to raise it. 

NOTE 

One-quarter turn of the adjustment screw changes the temperature setting  

approximately 24°F (13 °C).

 

 

f. 

Turn the adjustment screw until the burners energize at 325°F (163 °C).  
 

g. 

Replace the knob and allow the appliance to cycle 4 to 6 times. Check the temperature of the 
digital thermometer against the thermostat dial setting; if there is greater than a 5 °F (3 °C) 
difference, repeat the calibration procedure. 

 
 

Содержание SLG Series

Страница 1: ...Please complete this information and retain this manual for the life of the equipment Model __________________________ Serial __________________________ Date Purchased ___________________ Installation...

Страница 2: ...ance with a water jet NOTICE Installation of this appliance should only be performed by a competent service technician The model serial number and technical requirements of this appliance are on the d...

Страница 3: ...ety Systems 2 Initial Preparation Initial Cleaning 2 Operation Filling the Tank Filling the Tank with Liquid Shortening oil 3 Filling the Tank with Solid Shortening oil 3 Operating Instructions Applia...

Страница 4: ...n not be curb mounted Curb mounting may seriously inhibit this appliance s ability to operate properly WARNING This appliance must be installed with the legs or casters provided by the manufacturer WA...

Страница 5: ...45 7 cm of open space between the flue opening and the intake of the exhaust hood Electrical Connection if applicable Your Anets appliance is manufactured to operate on a particular electrical supply...

Страница 6: ...d solid shortening oil can be used in this appliance but liquid is preferred If solid shortening oil is used it is recommended that you melt the shortening oil before adding it to the appliance You ca...

Страница 7: ...ortening oil Dropping liquid or frozen foods into the hot shortening oil will cause violent boiling Appliance Start Up WARNING DO NOT start the appliance without filling the tank with shortening oil f...

Страница 8: ...he following procedure for weekly boil out WARNING Completely shut the appliance down when the shortening oil is being drained and replaced with water This will prevent the burners from energizing whi...

Страница 9: ...setting If the values are more than 5 F 3 C apart calibrate the thermostat using procedure in this manual Thermostat Calibration For Gas Thermostats refer to the following procedure a Remove the bask...

Страница 10: ...emperature properly Faulty or improperly calibrated thermostat faulty hi limit switch Main burners do not shut off Faulty gas valve faulty thermostat Oil Shortening does not reach desired temperature...

Страница 11: ...appliance down using the Appliance Shut Down procedure in this manual turn off the gas supply to the appliance and repair the leak When the leak has been repaired repeat step k in this procedure and c...

Страница 12: ...event of problems with or questions about your equipment please contact the Anets Authorized Service and Parts representative ASAP covering your area or contact Anets at the number listed to the left...