TROUBLESHOOTING AND CONVERSION
8
L20-352-UK Rev.1 08/12
f.
Reinstall the burners array into the appliance.
g.
Reinstall the modified pilot assembly into the appliance.
h.
Apply the gas type conversion label, provided with the conversion kit, just below the data plate
(located on the inside of the appliance door).
i.
Ensure that all steps of this procedure have been executed properly and that ALL gas
connections are connected and retightened.
j.
Connect a manometer to the pressure test point on the burner manifold.
k.
Turn the gas supply to the appliance on and start the appliance using the Appliance Start Up
procedure in this manual.
l.
Using leak detector fluid, check ALL gas connections and orifice tips for leakage. If gas leakage
is detected shut the appliance down using the Appliance Shut Down procedure in this manual,
turn off the gas supply to the appliance and repair the leak. When the leak has been repaired
repeat step ‘k’ in this procedure and continue through the procedure.
m.
With the main burners on, ensure that the burner pressure is correct for the gas type to which
you have converted the appliance. Adjust the burner pressure, if necessary, by removing the cap
screw on the gas valve regulator and turning the adjustment screw clockwise to increase burner
pressure, counter-clockwise to decrease burner pressure. Replace regulator cap screw when
finished.
Gas Conversion Information and Specifications
M
odel
F
uel
T
y
pe
G
as
A
ppl
ianc
e
C
at
egor
y
B
ur
ner
P
res
s
ur
e
(m
b
a
r)
B
u
rn
e
r O
ri
fi
c
e
P
ilo
t O
rif
ic
e
C
ode
G
ov
er
nor
SLG40
NAT
G20
I
2H
8.7
#31
N22
Yes
NAT
G25
I
2L
8.7
3.4 mm
N22
Yes
LP
G31
I
3P
25.4
1.9 mm
LP16
Yes
SLG100
NAT
G20
I
2H
8.7
#34
N22
Yes
NAT
G25
I
2L
10.0
#31
N22
Yes
LP
G31
I
3P
25.4
#51
LP16
Yes