GPC-14/18 
PASTA COOKER 

INSTALLATION INSTRUCTIONS 

 
 
 
 
 

1. 

The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1 latest edition, 

CAN/CGA -B149.1 & B149.2, Natural Gas Installation Code as applicable including: 

a. 

The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of 

the system at test pressures in excess of ½ psig (3.45 kPa). 

b. 

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure 

testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.45 kPa). 

c. 

For units utilizing optional floor casters, the installation shall comprise of a connector that complies with the Standard for Connectors for 

Moveable Gas Appliances, ANSI Z21.69, or CAN/CGA 6.16-latest edition, and a quick-disconnect device that complies with the 

Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41 or CAN1-6.9 “latest edition.” 

d. 

Adequate means must be provided to limit the movement of the unit without depending on the connector and the quick-disconnect 

device or its associated piping to limit the appliance movement (when appliance is equipped with optional casters).  The limiting cable is 

supplied by the installation contractor.  It is connected to the rear of the unit through the 5/16 dia. hole.  The other end is attached to 

the wall near the supply fitting.  Refer to diagram 

B

2. 

For use only in non-combustible locations. Keep the appliance area free and clear from combustibles. Suitable for installation on non- 

combustible floors only. 

3. 

The area that the unit is installed into should have provisions for an adequate air supply for proper burner operation and the flow of 

combustion and ventilation air must not be obstructed.  The bottom and back of the unit must be kept open so that the burners will be able to 

draw enough air for proper operation.  The area directly in front of the unit must be kept open so that the unit can be serviced. 

4. 

The appliance must be installed under a vent or exhaust hood to exhaust the cooking smoke and fumes and the products of combustion in 

accordance with the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96. 

5. 

The unit must be installed with the proper clearances to combustible materials; refer to diagram 

C

 
 
 
 
 

6. 

Make sure the unit’s pilot safety valve(s) are in the “OFF” position and turn on the main gas supply.  Check for gas leaks using a soap 

solution. 

7. 

Restrain the unit to prevent tipping when installed in order to avoid the splashing of hot liquid.  The means of restraint may be the manner of 

installation, such as connection to a battery of appliances, or installed in an alcove, or by separate means, such as adequate ties. 

8. 

This appliance is equipped with a 3-prong (grounding) plug and must be plugged into a properly grounded three-prong receptacle. 

grounding must comply with local codes, or in the absence of local codes, with the National Electrical Code ANSI/NFPA No. 70, or the 

Canadian Electrical Code, CSA C22.2, as applicable. 

9. 

Cooker drain terminates at drain valve.  Connect plumbing per local and national codes. 

10. 

After completion of proper hook-up and installation according to code, the unit may be operated. 

 

NOTE: 

The installer should contact local building or fire officials concerning any installation restrictions or the need for inspection of the cooker 

installation. 

 

 

 

 

Electrical 

NOTICE! 

DO NOT pack required air spaces with insulation or other material. 

IMPORTANT! 

Read all Installation Instructions carefully before starting the installation. 

Failure to follow instructions may result in property damage, bodily injury or death. 

DANGER! 

When this cooker is not properly installed, a fire may result. 

To reduce the risk of fire, follow all installation instructions. 

Содержание PASTA PRO GPC-14

Страница 1: ...nformation must be posted in a prominent location WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating a...

Страница 2: ...the unit for the appliance wiring diagram LEG CASTER INSTALLATION 1 Carefully lay cooker on its back and install legs or casters as shown in diagram A below 2 After placing unit in installation area a...

Страница 3: ...t be obstructed The bottom and back of the unit must be kept open so that the burners will be able to draw enough air for proper operation The area directly in front of the unit must be kept open so t...

Страница 4: ...Pilot must be turned off if cook tank is empty POWER BURST 18 and 20 Pasta Cookers are equipped with the Power Burst System The Power Burst toggle switch is located on the front of the unit Hard Boil...

Страница 5: ...eck the burner tube baffles located inside the burner tube on 18 20 tube fired models to ensure that they are not deteriorated beyond their useful life If baffles need to be replaced contact the facto...

Страница 6: ...under LIGHTING AND SHUT DOWN section If the pilot is burning turn the knob to the ON position Turn the thermostat knob to a higher set point Check incoming gas pressure If the pilot is burning the sa...

Страница 7: ...wire and NO right motor blue left motor brown If the motor operates the timer has failed and must be replaced If the motor does not operate the microswitch or motor may have failed Set a time value us...

Страница 8: ......

Страница 9: ...NOTES...

Страница 10: ...please contact the Anets your equipment please contact the Anets factory at Authorized Service and Parts representative 603 225 6684 World Wide ASAP covering your area or contact Anets Website Address...

Отзывы: