7
L22-371 Rev 0 2/13
CAUTION
If the burners do not shut off at the LOWEST thermostat setting, the thermostat may be
defective. Contact your local service company.
2.4 Thermostat Calibration
For Gas Operated and Electric Thermostats refer to the following procedure.
a.
Remove the tube screen from the tank and place the tip of a digital thermometer in the
shortening/oil approximately one inch above the temperature sensor.
b.
Light the pilot as described in this manual, set the thermostat to 325°F (163 °C) and allow the
shortening/oil to come up to temperature; let the appliance cycle 4-6 times to insure that the
shortening/oil temperature has stabilized. Compare the thermostat setting of 325°F (163 °C) to
the digital thermometer reading.
c.
Remove the thermostat dial by pulling the knob straight out. DO NOT rotate the dial.
d.
Holding the outside of the shaft so that it
DOES NOT MOVE
, scrape away the sealing
compound in the center of the shaft with a small flat blade screwdriver.
e.
Turn the adjustment screw clockwise to lower the thermostat’s temperature setting or counter-
clockwise to raise it.
NOTE
One-quarter turn of the adjustment screw changes the temperature setting
approximately 24°F (13 °C).
f.
Turn the adjustment screw until the burners come on at 325°F (163 °F).
g.
Replace the knob and allow the appliance to cycle 4 to 6 times. Check the temperature of the
digital thermometer against the thermostat dial setting; if there is greater than a 5°F
(3 °C) difference, repeat the calibration procedure.
Содержание 14GS Series
Страница 10: ...14GS CS Series 10 L22 371 Rev 0 2 13 4 14GS Fryer Exploded View...
Страница 12: ...14GS CS Series 12 L22 371 Rev 0 2 13 5 Gas Manifold with Pilot Exploded View...
Страница 14: ...14GS CS Series 14 L22 371 Rev 0 2 13 6 Gas Supply Stand Alone Exploded View...
Страница 16: ...14GS CS Series 16 L22 371 Rev 0 2 13 7 Gas Supply With Filter Exploded View...