background image

 

L22-371  Rev 0 2/13

 

CAUTION 

If the burners do not shut off at the LOWEST thermostat setting, the thermostat may be 

defective. Contact your local service company. 

 

2.4 Thermostat Calibration 

For Gas Operated and Electric Thermostats refer to the following procedure. 
 
a. 

Remove the tube screen from the tank and place the tip of a digital thermometer in the 
shortening/oil approximately one inch above the temperature sensor. 

b. 

Light the pilot as described in this manual, set the thermostat to 325°F (163 °C) and allow the 
shortening/oil to come up to temperature; let the appliance cycle 4-6 times to insure that the 
shortening/oil temperature has stabilized. Compare the thermostat setting of 325°F (163 °C) to 
the digital thermometer reading.  

c. 

Remove the thermostat dial by pulling the knob straight out. DO NOT rotate the dial. 

d. 

Holding the outside of the shaft so that it 

DOES NOT MOVE

, scrape away the sealing 

compound in the center of the shaft with a small flat blade screwdriver. 

e. 

Turn the adjustment screw clockwise to lower the thermostat’s temperature setting or counter- 
clockwise to raise it. 
 

NOTE

 

One-quarter turn of the adjustment screw changes the temperature setting  
approximately 24°F (13 °C). 

 

f. 

Turn the adjustment screw until the burners come on at 325°F (163 °F).  

g. 

Replace the knob and allow the appliance to cycle 4 to 6 times. Check the temperature of the 
digital thermometer against the thermostat dial setting; if there is greater than a 5°F  
(3 °C) difference, repeat the calibration procedure. 
 

 
 
 
 
 
 
 
 
 
 

Содержание 14GS Series

Страница 1: ...NCE Please complete this information and retain this manual for the life of the equipment Model __________________________ Serial __________________________ Date Purchased ___________________ Service...

Страница 2: ...training cable must be connected at all times when the appliance is in use WARNING An appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnec...

Страница 3: ...ouble Shooting 8 3 1 Testing the Thermocouple 9 3 2 Testing the Radix wire 9 3 3 Testing the Hi Limit 9 3 4 Testing the Gas Valve 9 4 14GS Fryer Exploded View 10 4 1 14GS Fryer Parts List 11 5 Gas Man...

Страница 4: ...ons and will allow for safe and proper operation of your appliance Combustible Construction Non Combustible Construction Back 6 in 15 cm 6 in 15 cm Sides 6 in 15 cm 6 in 15 cm Floor N A 4 11 5 cm For...

Страница 5: ...t c Review the installation portion of this manual and ensure that all steps have been followed and executed properly 2 1 Pilot Flame Adjustment after gas valve replacement For manual pilots refer to...

Страница 6: ...p e if it is not adjust the pressure as outlined in step d d To adjust the pressure remove the regulator adjustment screw cap on the gas valve and with a flat head screwdriver adjust the regulator scr...

Страница 7: ...ized Compare the thermostat setting of 325 F 163 C to the digital thermometer reading c Remove the thermostat dial by pulling the knob straight out DO NOT rotate the dial d Holding the outside of the...

Страница 8: ...rged from the pilot gas line YES NO Is high limit switch open YES Will high limit switch reset YES Reset switch and light pilot Contact a qualified service technician NO NO Does pilot go out when the...

Страница 9: ...nd inspect both sides of that butterfly connector Make sure the wires aren t broken and then check for continuity through it If it is bad the part number is B6779850 3 3 Testing the Hi Limit Press the...

Страница 10: ...14GS CS Series 10 L22 371 Rev 0 2 13 4 14GS Fryer Exploded View...

Страница 11: ...PER A3682302 FRONT PANEL STAND ALONE A3681202 FRONT PANEL WITH FILTER A3680402 FRONT PANEL END CAP LH A3680404 FRONT PANEL END CAP RH A3680702 FRONT PANEL MIDDLE CAP 5 P9204 75 ANETS NAME PLATE BLACK...

Страница 12: ...14GS CS Series 12 L22 371 Rev 0 2 13 5 Gas Manifold with Pilot Exploded View...

Страница 13: ...9 ORIFICE RUNNER TUBE NAT P8904 99 ORIFICE RUNNER TUBE LP P8904 74 ORIFICE RUNNER TUBE CE LP P8840 96 BURNER JET NAT P8840 95 BURNER JET LP A8047401 BURNER JET CE NAT A8047402 BURNER JET CE LP A804740...

Страница 14: ...14GS CS Series 14 L22 371 Rev 0 2 13 6 Gas Supply Stand Alone Exploded View...

Страница 15: ...1 2 NPT CLOSE 8 60127501 FITTING ADAPTOR MALE FLARE X FNPT 9 60128016 GAS SUPPLY FLEX TUBE 28 10 A8029105 GAS SUPPLY COUPLING 11 60179801 INTERUPTOR 11 32 THREAD 12 60132801 PRESSURE TEST FITTING 13...

Страница 16: ...14GS CS Series 16 L22 371 Rev 0 2 13 7 Gas Supply With Filter Exploded View...

Страница 17: ...LARE BY 1 2 NPT 8 60127501 FITTING ADAPTOR MALE FLARE X FNPT 9 60128014 GAS SUPPLY FLEX TUBE 16 10 A8029105 GAS SUPPLY COUPLING 11 60179801 INTERUPTOR 11 32 THREAD 12 60132801 PRESSURE TEST FITTING 13...

Страница 18: ...16 TH PHILLIPS 5 PP10539 KNOB THERMOSTAT 6 P0007300 SCREW 8 32 X 1 4 HEX HEAD ZINC 7 B6744402 WIRING MILLIVOLT HI LIMIT THERMOSTAT 8 P9132 34 CONTROL SPARK IGNITOR 9 60172101 BATTERY TRIPLE A 1 5V 10...

Страница 19: ...WIRING MILLIVOLT HI LIMIT THERMOSTAT 8 P9132 34 CONTROL SPARK IGNITOR 9 60172101 BATTERY TRIPLE A 1 5V 10 60167801 CONTROL WIRE SPARK IGNITOR 24 11 P9132 37 CONTROL SPARK IGNITOR GROUND WIRE 12 P9204...

Страница 20: ...vent of problems with or questions about your order please contact the Anetsberger Factory at 001 603 225 6684 World Wide In the event of problems with or questions about your equipment please contact...

Отзывы: