2. SAFETY WARNING

FIRE AND EXPLOSION

1. Never use the following HALOGENATED HYDROCARBON SOLVENTS:

which can cause cracks or dissolution of gun body (aluminium) due to 
chemical reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloro-
methane, 1.2-dichloroethane, carbon tetrachloride,  trichloroethylene, 
1.1.1-trichloroethane                          

2. Sparks and open flames are strictly prohibited.

Paints can be highly 

flammable and can cause fire.Do not expose to open flames, electrical 
goods, cigarettes etc.

3. Securely ground spray gun using conductive air hose. 

(Less than 1M

Ω

Always ensure that the spray gun is earthed correctly.

PROTECTION OF HUMAN BODY

1. Use in a well-ventilated site, using a spray booth.

Poor ventilation can cause organic solvent poisoning and fire.

2. Always wear protective gear (safety glasses, mask, gloves) to avoid 

inflammation of eyes and skin.

In case of any physical discomfort, immediately seek medical advice.

3. Wear earplugs if necessary.

Noise level can exceed 80 dB(A), depending on operating conditions and 
painting site.

4. Pulling the trigger many times during operation, may cause carpal 

tunnel syndrome

. Always rest, in case of tiredness.

GB

ALWAYS observe WARNINGS and CAUTIONS in this 
instruction manual.

1. TECHNICAL SPECIFICATIONS

This  ANEST IWATA spray guns kit complies
to ATEX regulations 94/9/EC, protection level:
II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be
diverted to the ground via the conductive air hose as stipulated. 

Before use, adjustment or maintenance, it is important
to read this instruction manual very carefully. This ma-

nual must be stored in a safe place for any future reference.

IMPROPER USE

1.  Never point gun towards people or animals.

2.  Never exceed maximum working pressure or maximum operating 

Temperature

3.  Always release air and fluid pressure before cleaning, disassembling 

or servicing.

Otherwise, remaining pressure can cause bodily injury due 

to improper operation or scattering of cleaning liquid.

4.  Tip of fluid needle set has a sharp point. 

Do not touch the tip during maintenance to avoid accidents.

5. Never use this gun to spray foods or chemicals. 

Otherwise, foreign substance, could cause corrosion of fluid passages 
which could adversely affect health.

6. Never alter this spray gun, 

to avoid insufficient performance and dam-

age.

7. If something goes wrong, immediately stop operation and find the 

cause. Do not use again, until you have solved the problem.

8. Do not enter working areas, where robots, reciprocators, etc. are used,

until they have been turned off. 

Otherwise, they could cause injury.

3. HOW TO USE

CAUTION

-

Use clean air filtered through air dryer and air filter.

-

When using this gun for the first time after purchase, adjust fluid nee-
dle packing set (3), spray cleaner to clean fluid passages and  remove 
rust preventive oil.

-

Firmly fix hose or container to spray gun, to avoid disconnection of 
hose or container, that can cause bodily injury.

1. Firmly connect an air hose to air nipple 1/4”(4-2).

2. Firmly connect a suitable cup to fluid nipple (4-1).

3. Flush fluid passages with a compatible solvent.

4. Pour paint into container, test spray, adjust fluid output and pattern width.

4. HOW TO OPERATE

_ Suggested atomizing air pressure is 1.5 to 2.5 bar (21 to 36 PSI).

_ Recommended paint viscosity differs according to paint property and 

painting conditions. 14 to 25 sec. / Ford cup#4 is recommended.

_ Set the spray distance from the gun to the work piece, as near as possi-

ble within the range of 130-200 mm.

_ The gun should be held so that it is perpendicular to the surface of the 

workpiece at all times. Then, the gun should move in a straight and hori-
zontal line. Arcing the gun causes uneven painting.

5. MAINTENANCE AND INSPECTION

CAUTION

-

Never use spare parts that are not Anest Iwata originals.

-

Never damage fluid nozzle tip, fluid needle or air cap holes.

-

Never immerse the spray gun completely in liquids such as thinner.

5.1 MANUAL CLEANING PROCEDURE

Max. working air pressure: 7.0 bar (100 PSI)

Air connection:

G 1/4”M

Noise Level (LAeqT)*:

75.8 dB (A) 

Fluid connection:

G 1/4”F

Max. Temperature range:

5 ~ 40 °C

Weight g (lbs)**:

475 (1.05)

Symbol

WARNING

Hazard level

Consequence

WARNING

Potentially hazardous  Death or serious injury
situation

CAUTION

Potentially hazardous  Minor to moderate injury
situation

IMPORTANT

Potentially hazardous  Property damage
situation

Before carrying out maintenance and inspection ALWAYS
observe WARNING indications.

The fluid passages of the gun, must be cleaned thoroughly 
after each use, especially after use with bi-component paints. 
Incomplete cleaning can cause defective pattern shape.

Model

Nozzle  Air cap

Fluid 

Air 

Pattern

Pattern

size

set Mark output consumption

Width

Width

EVO= (*)

Ø 

ml/min 

Nl/min 

at 130 mm  at 200 mm

Air pressure at gun inlet 2 bar

WS400-1201*

1.2 

120

250

350

WS400-1301B*

Base 1.3 

140

260

365

WS400-1301C*

Clear 1.3 

170

260

365

WS400-1401B*

Base 1.4 

170

260

365

WS400-1401C*

Clear 1.4 

190

260

370

WS400-1301BH*

220

265

365

WS400-1301CH*

220

265

365

WS400-1401BH*

240

270

370

WS400-1401CH*

240

270

370

WS400-1501BH*

260

275

370

WS400-1501CH*

260

275

370

WS400-1301OBS*

Base 1.3

160

260

365

WS-400-

01

1.3 HD
(1.3.2)

1.4 HD
(1.4.2)

1.5 HD
(1.5.2)

370

* Measuring point: 1m backwards from gun, 1.6m height.          ** Weight without cup.

European Directives: 
1994/9/CE - 1999/92/CE 