Maintenance and inspection 

 

 

How to carry out maintenance 

 

Intake filter 

Blow dust off the filter with an air gun and replace if it is dirty. 

 

Belt tension 

If the V belt makes a slipping sound at the startup, due to decrease of V belt tension, readjust the belt tension or 
replace it.   
If the belt tension is less than the figure in the chart below, adjust the belt tension again. 
An exclusive tool is necessary to measure belt tension. 
Ask our distributor to readjust belt tension when needed. 

       

Model 

Readjustment   

standard load / Hz 

Readjustment   

target load / Hz 

Tolerance

 

±5 

Replacement new belt 

target load / Hz   

Tolerance

 

±5 

SLVB-5 

75 

98 

105 

 
 
 
 
 
 
 
 
 
 

 

Содержание SLVB-5

Страница 1: ...eration be sure to read this instruction manual thoroughly for safe and efficient use for a long operating lifetime After reading it store in a convenient place for immediate and future reading Before...

Страница 2: ...of warnings and cautions WARNING May cause injury or death CAUTION May result in injury or property damage Examples of warnings and cautions May cause electric shock Do not touch Must be grounded Supp...

Страница 3: ...f the main electric source To prevent electric shock or serious injury always turn off the main electric source before inspecting or servicing the unit Ask a qualified electrician Only a qualified ele...

Страница 4: ...s and fingers away from fans pulleys and belts while the power is on Serious injury including entanglement of fingers or hands can occur Release pressure Release pressure from unit before conducting m...

Страница 5: ...orrosive gas Failure to do so may result in equipment failure Only qualified personnel should perform repairs to prevent electric shock or fire Keep Away Keep away from the compressor while it is oper...

Страница 6: ...ion Precaution about installation 7 Installation space 8 Ventilation 8 Test operation Operation 9 Maintenance and inspection Pump Motor Assembly maintenance standards 10 How to carry out maintenance 1...

Страница 7: ...pan of the unit WARNING To prevent a fire or explosion install in an area free of flammable gases or organic solvents Ambient temperature Use at ambient temperatures of 36 F to 104 F Using at less tha...

Страница 8: ...space around the compressor for safe inspection and maintenance Installation space inch Above 24 Front side 40 Other Sides 20 Ventilation When using in an enclosed room install a fan for ventilation...

Страница 9: ...ation and check pressure increase 1 Switch the electric source breaker on 2 Be sure the pressure increases when the compressor starts 3 Check that the compressor operates without excessive vibration u...

Страница 10: ...rks Operational hours Daily Every 400hrs Every 2months Every 2 500hrs Every 1 year Every 5 000hrs Every 2 years Every 10 000hrs Every 4 years Every 20 000hrs Every 8 years Every 30 000hrs Every 12year...

Страница 11: ...decrease of V belt tension readjust the belt tension or replace it If the belt tension is less than the figure in the chart below adjust the belt tension again An exclusive tool is necessary to measur...

Страница 12: ...loose Inspect tighten or replace drive belts Clogged intake filter element Clean or replace intake filter element Discharge air is leaking Inspect and repair Pump has failed Inspect repair or replace...

Страница 13: ...arge air temperature F Ambient temperature less than 342 Air outlet JIC Motor Operating voltage Single Phase 208 230V 60Hz Output HP 5 Others Dimensions L W H inch 2 17 x 20 x 26 Approx mass Lbs 190 N...

Страница 14: ...14 Appendix Outer dimensions...

Страница 15: ...anty provided herein shall not apply to i any defects arising from corrosion abrasion use of insoluble lubricants or negligent attendance to or faulty operationoftheproducts ii ordinarywearandtearofth...

Страница 16: ...16...

Отзывы: