ATTENTION

When you try to make a nozzle, refer to the figures below.

Sealing job

WARNING
During materialing, be sure to wear protective cover such as glasses, mask or gloves to avoid serious 
injury caused by material or solvent which might enter your eyes or you might  inhale.

CAUTION
Before you use new flow gun for the first time, clean its inside. If not done, rust preventive inside gun can 
cause sealing failure.

ATTENTION
As fluid pressure increases, fluid output increases with increasing wear on parts. For longer life span of 
flow gun, adjust fluid pressure as low as you can, maintaining satisfactory fluid output.

CLEANING AND MAINTENANCE

In order to get longer lifetime of flow gun and good performance at the next job, fully clean its inside with 
cleaning liquid which is compatible with material used, after you finish the job.

WARNING
During materialing, be sure to wear protective cover such as glasses, mask or gloves to avoid serious 
injury caused by paint or solvent which might enter your eyes or you might inhale.

Be sure to stop pump and reduce fluid pressure down to 0 pressure before disassembling flow gun.

Only an experienced person who is fully conversant with the equipment can do maintenance and inspec-

tion.

CAUTION
Never use commercial or other parts instead of ANEST IWATA original spare parts.

No damage should be made on 
tapered section

Nozzle

less than 5

nozzle holder

nozzle gland set

PROBLEMS AND REMEDIES

IMPORTANT 

: As for * marked items, ask our distributor to remedy it for you.  Incorrect remedy cannot achieve satisfactory

performance.

Problem

Where

Cause

Remedies

Material does not 

Nozzle tip is clogged.

Ispect or replace.

come out.

Material is not fed.

Inspect pump.

Material leaks or

Nozzle(Material leaks 

Pump pressure is high.

Reduce pump pressure down 

comes out weakly.

from of nozzle) 

to 150bar (2142PSI).

Flow resistance in pump is too high.

Use material of lower viscosity.

• Material viscosity is high.

Use collar [13] or nozzle with larger 

• Nozzle orifice is small.

orifice.

Material or dust sticks to
needle packing [5-6].
Material or dust sticks to

Disassemble, inspect

needle seat [4].

or replace part*

Seat between needle bar set [7-11] 
and nozzle gland set [3] is worn.
Needle bar set [5-1] is over- tightened. Adjust by needle spring holder [5-8].

Nozzle gland set [2]

Nozzle gland set [2] is loose.

Tighten.

Needle spring seat [7]  Needle packing seat [5-7] is loose.

Tighten with

needle seat[4]

needle spring holder [5-8].

Needle packing [5-6] is worn, damaged  Tighten with
or stuck with material or dust.

needle spring holder [5-8].
Disassemble, inspect 
or replace part.

Needle bar set [5-1] is worn, damaged  Tighten with
or stuck with material

needle spring holder [5-8].
Disassemble, inspect 
or replace part.

Nozzle holder [1]

Nozzle gland set [2] and taper 

Disassemble, inspect 

section of nozzle are damaged or 

or replace part.

stuck with material or dust
Nozzle holder [1] is loose.

Tighten.

Universal joint [11]

Wear of packing in universal joint

Replace universal joint.