Anemoment LLC
25
Data Logger 422 User Manual
Chapter 9: Data Variables Configuration – Menu
Commands
Access Menu Interface Mode by Using a Serial Terminal
The user must provide a serial terminal emulation program to interface
with the DL422.
Suitable software programs available online include (but are not limited to)
TeraTerm
,
RealTerm
or
PuTTY
.
To use the Menu Interface Mode the user must connect the DL422 to the computer on which the
serial terminal emulation program has been loaded. This connection may be made in three different
ways:
1.
Connect the DL422 USB-Mini-B port
(Figure 10) to a PC USB-A
by using a user supplied USB A to Mini-B cable. The user’s PC
then creates a virtual communications port for the terminal
emulation program to connect through.
2.
Connect to the Radio port of the DL422 by using an external
UART to USB adapter. When this adapter is inserted into the
PC’s USB connector, the user’s PC creates a virtual
communications port for the terminal emulation program to
connect through.
3.
Connect the DL422 external serial port to another computer
system that uses a UART interface.
7
To access the DL422-E-Series unit USB-Mini-B port, remove the four screws from the base of the weather-
tight enclosure and lift the lid. After the DL422-E-Series unit has been configured to the user’s desired
specifications, replace the lid on the gasket and inspect that the gasket is positioned correctly between the lid
and the base; then replace and tighten the four screws.