22
5.3 - INSTALLING THE HYDRAULIC MOTOR
Connecting the hydraulic motor
Remove the protective plug.
Hydraulic motor mountings are available in two versions:
a) Version with O-ring oil gasket between motor flange and gear unit.
In this case, mount the gasket to ensure an oil tight seal between the motor and gear unit, taking care to fit it
correctly in its seat without damaging it.
³
8.8
b) Version with gasket already mounted to the coupling.
In this case no special intervention is required to ensure an oil tight seal since this is already provided by the
motor coupling. Merely smear the motor shaft with grease.
In both cases, clean the spigot and the coupling where the motor is to be fitted, fit the motor and tighten
down the flange mounting bolts.
Always use bolts rated to at least class 8.8.
³
8.8
Luggage Point STP ST18 Pre Treatment (Aqua-Screen (Andritz) Operation and Maintenance Manual) General
Q-Pulse Id: TMS579
Active: 13/12/2013
Page 295 of 316