ANDREWS COMBIfl o
57
GB
6.2.8 SPARK AND IONISATION ELECTRODES
These are located on the front of the heat exchanger.
Spark electrode
Ionisation electrode
• Carefully pull off the electrical connectors.
• Undo the two screws retaining the bracket and withdraw.
• Replacement is the reverse ensuring that the gasket seal is placed correctly and is in good condition.
6.2.9 PLATE HEAT EXCHANGER
Remove condense tube Release heat exchanger
connections (X4)
Remove screws from either side of
plate heat exchanger
• Remove the lower left hand side cover to gain better access to the heat exchanger
• Remove the condense pipework from behind the heat exchanger.
• Remove the two crosshead screws, located either side of the heat exchanger.
• Drain as much of the primary and secondary systems water as possible, to reduce water spillage.
• Release all four heat exchanger connections and slide the heat exchanger toward the rear, and remove
sideways
• Replacement is the reverse.
Содержание COMBIflo 100/300
Страница 9: ...ANDREWS COMBIflo 7 GB 3 1 GENERAL DIMENSIONS CONNECTIONS 3 0 TECHNICAL DATA ...
Страница 12: ...ANDREWS COMBIflo 10 GB 3 4 APPLICATION EXAMPLES Single Heating Circuit Simple ...
Страница 13: ...ANDREWS COMBIflo 11 GB Single Heating Circuit Immersion DHW Circulation pump ...
Страница 16: ...ANDREWS COMBIflo 14 GB Heating Circuit External 0 10V control ...
Страница 17: ...ANDREWS COMBIflo 15 GB BMS INTERNET CONNECTIONS ...
Страница 18: ...ANDREWS COMBIflo 16 GB 3 5 WIRING DIAGRAMS PCB 1 ...
Страница 19: ...ANDREWS COMBIflo 17 GB PCB 2 3 ...
Страница 69: ...ANDREWS COMBIflo 67 GB 6 4 COMPONENT ILLUSTRATIONS CONTINUED 1 2 3 4 5 29 8 9 11 6 13 12 7 39 40 41 42 35 10 30 ...
Страница 70: ...ANDREWS COMBIflo 68 GB 32 24 24 24 26 25 23 27 6 4 COMPONENTS ILLUSTRATIONS CONTINUED 32 27 15 33 14 10 28 ...
Страница 76: ...M7889 Rev N Mar 2022 March 2022 ...