User’s Manual for Node G
Network Elements
Page 46
M0121A2A.doc
Pin 3
Pin 1
Pin 2
4.3.7.3. Summary
Alarm
The summary alarm is a DC potential-free contact relay.
Observe that the cross-sectional area of the wires to be connected must be in the
range from 0.14 - 1.5 mm
2
.
Pin No.:
1
2
3
figure 4-22 Summary alarm relay
The following table indicates the three-connector pin out.
Pin No.
Contact
Maximum Resistive Load
1
Open in alarm condition
Max 1 A @ 50 VDC
2
Common
Max 2 A @ 30 VDC
3
Closed in alarm condition
Max 1 A @ 230 VAC
table 4-2 Pin assignment of relay contacts
figure 4-23 Relay contacts, alarm condition
Содержание Node G 930
Страница 1: ...ID No 7164491 Page 1 User s Manual for Node G Network Elements ...
Страница 12: ...User s Manual for Node G Network Elements Page 12 M0121A2A doc For your notes ...
Страница 16: ...User s Manual for Node G Network Elements Page 16 M0121A2A doc For your notes ...
Страница 28: ...User s Manual for Node G Network Elements Page 28 M0121A2A doc For your notes ...
Страница 52: ...User s Manual for Node G Network Elements Page 52 M0121A2A doc For your notes ...
Страница 53: ...6 Illustrations ID No 7164491 Page 53 6 ILLUSTRATIONS 6 1 CABINET DRAWINGS figure 6 1 Cabinet of a Node G ...
Страница 55: ...6 Illustrations ID No 7164491 Page 55 figure 6 3 Layout of the Node G x38 exemplaryx30 exemplary ...
Страница 56: ...User s Manual for Node G Network Elements Page 56 M0121A2A doc For your notes ...
Страница 62: ...User s Manual for Node G Network Elements Page 62 M0121A2A doc For your notes ...