ION

®

-M17P/19P Advanced 

Optical Remote Unit 

 

 

 

(M-Cabinet) 

 
 

Manual 

MF0145AXA 

 

Содержание CommScope ION-M17P Advanced

Страница 1: ...ION M17P 19P Advanced Optical Remote Unit M Cabinet Manual MF0145AXA...

Страница 2: ...not cover the performance under adverse or disturbed conditions Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purpose...

Страница 3: ...cal Installation 15 4 1 2 Property Damage Warnings for Mechanical Installation 15 4 1 3 Wall Mounting Procedure 17 4 1 4 Pole Mounting 18 4 1 5 Mounting of Fan Protection 20 4 2 ELECTRICAL INSTALLATIO...

Страница 4: ...e 4 3 Pole mounting metric dimensions 19 figure 4 4 Mounting procedure for fan protection metric dimensions 20 figure 4 5 Connector flange of ION M17P 19P Advanced 22 figure 4 6 Grounding bolt left an...

Страница 5: ...for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3rd order ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Orga...

Страница 6: ...avoid the possibility of close proximity to the antenna s while in operation 1 3 Property Damage Warnings 1 Attention Due to power dissipation the remote unit may reach a very high temperature Do not...

Страница 7: ...in minus the loss between the repeater and the antenna PD mW cm is the allowed Power Density limit acc to 47 CFR 1 1310 B for general population uncontrolled exposures which is o F MHz 1500 for freque...

Страница 8: ...itif Cet appareil est conforme avec Sant Canada Code de s curit 6 Le programme d installation de cet appareil doit s assurer que les rayonnements RF n est pas mis au del de I exigence de Sant Canada L...

Страница 9: ...correct the interference at his own expense 8 Note This unit complies with European standard EN60950 Equipment Symbols Used Compliance Please observe the meanings of the following symbols used in our...

Страница 10: ...hensive quality monitoring is conducted at all fabrication stages Finished products leave the factory only after a thorough final acceptance test accompanied by a test certificate guaranteeing optimal...

Страница 11: ...o City Mexico Phone 1 815 546 7154 Cell 55 15 9104 7722 Office Phone 52 55 1346 1900 Office Fax 55 15 2102 4001 Fax 52 55 1346 1901 E mail wisupport commscope com E mail wisupport commscope com China...

Страница 12: ...zerland Andrew Wireless Systems Austria GmbH CommScope Wireless Systems AG Mail Weglgasse 10 2320 Wien Schwechat Austria Mail Tiergartenweg 1 CH 4710 Balsthal Switzerland Phone 43 1706 39 99 10 Phone...

Страница 13: ...aster Unit depends on the number of the Remote Units and the frequency range WDM Wave Division Multiplex filters are integrated in the optical modules For the UL a wavelength within 1546 nm 1550 nm is...

Страница 14: ...rotective cover to be mounted over the air inlet is delivered with the unit For more details see section 4 1 5 Mounting of Fan Protection Mounting of the fan protection kit is only mandatory for outdo...

Страница 15: ...falling due to improper installation The installer must verify that the supporting surface will safely support the combined load of the electronic equipment and all attached hardware and components T...

Страница 16: ...er The specifications for stationary use of the Remote Unit must not be exceeded Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site The mounting its...

Страница 17: ...ver the screws Hang the mounting brackets of the Remote Unit into the screws and fasten them immediately using the washers and nuts Ensure that there is free access to the electrical connections as we...

Страница 18: ...e the screw bands to fasten the two U beams to the pole as illustrated in figure 4 3 Pole mounting Note When fastening the U beams make sure that they are installed congruently and not at an angle to...

Страница 19: ...ge 19 G0764M6 Lock for folding screw band ES 119 TESPA screw band stainless 11 mm Optical Remote Unit Washer DIN 125 Form B 8 0 Lock washer for M8 0 DIN 127 A2 Form B Hexagon nut M8 DIN 934 Pole Pole...

Страница 20: ...ctive cover into the right position by fitting its four bore holes over the spacing bolts and fasten it using the original lock washers and screws of the Remote Unit These lock washers and screws are...

Страница 21: ...disconnecting the mains connector at the Remote Unit ensure that mains power supply is disconnected 5 Attention Make sure that an appropriate circuit breaker acting as a disconnect device as required...

Страница 22: ...front panels before connecting or disconnecting any cables 12 Notice Unused connectors must be closed with their protective covers to ensure watertightness 4 2 3 Connections figure 4 5 Connector flan...

Страница 23: ...o connect external devices figure 4 6 Grounding bolt left and schematic view right After loosening the hex nut connect the earth bonding cable between the two washers as illustrated in the above Then...

Страница 24: ...other tool e g a pair of pliers This might cause damage to the connector and lead to a malfunction of the RU Attention To minimize passive inter modulation PIM distortion attention has to be paid to...

Страница 25: ...ocedure and do not show the actual RU 1 What is needed for the cleaning a Isopropyl alcohol b Compressed air c Lint free wipe d Cotton buds 2 Remove protective cap from the RF connector 3 Remove metal...

Страница 26: ...ith isopropyl alcohol 6 Clean the inside surface of the inner ring with lint free wipe drenched with isopropyl alcohol 7 Clean the inside of the center conductor spring tines with a cotton bud drenche...

Страница 27: ...chips and small particles from the mating and inner surfaces of the connector using compressed air 10 Continue with the winding area using lint free wipe drenched with isopropyl alcohol 11 Continue wi...

Страница 28: ...strate the connection procedure and do not show the actual RU 1 What is needed for the connector assembly a Torque wrench b Adjustable counter wrench 2 Join the connectors and turn the coupling nut un...

Страница 29: ...m 18 0 ps nm km 1550 nm Fibre cable connectors E2000 APC 8 ION M system The pigtails for the connection between Master Unit and Remote Unit must have a sufficient length Protection for the optical fib...

Страница 30: ...ts dirt on the ferrule and scratches Connect the fiber optic cables by inserting the cable end into the laser receptacle and aligning the key on the cable end with the keyed slot Do not use any index...

Страница 31: ...ng followed immediately with a dry clean in order to ensure no residue is left on the endface 8 Repeat steps 5 through 7 until endface is clean Note For a more detailed description please refer to htt...

Страница 32: ...tor must be fitted into the stamp of the plug To release the contact for disassembling push the inner snap to the side and pull the contact out To release upper and lower insulation bodies for disasse...

Страница 33: ...or disassembling release the clamping ring and remove the seals and the plastic ring first Locking mechanism The system of locking the plug is based on a push pull mechanism The locking ring has to be...

Страница 34: ...lace the appropriate seal parts with one groove for one contact or two grooves for two contacts over the cable s and push them into the backshell Protective tube Reducer Coupling Protective plug Fiber...

Страница 35: ...section 7 3 Spare Parts Subminiature circular connectors series 712 with five and seven contacts which are contained in the alarm kit can be ordered directly from the Binder Connector Group the manufa...

Страница 36: ...monitor alarms with an external alarm indicator The 28 V pin pin 6 7 is specified to 28 VDC 0 5 A and is protected by a thermoswitch In case of exceeding this current between pin 7 and GND the thermo...

Страница 37: ...y Note Observe the applicable national regulations regarding loop impedance voltage drop and methods of installation Make sure to connect the correct voltage to the unit Note Do not connect or disconn...

Страница 38: ...r between mains and RU RF connection Connect antenna cable to antenna port Optical connections Mount the optical fibre with E2000 APC8 connector into the connector Plug the connector into the RU Mecha...

Страница 39: ...power of affected band VSWR alarm Check antenna and cable LED status Proceed to MU to set up the SW Orange Yes Internal Error Change power supply RUs with a door Reduce environmental temperature Elim...

Страница 40: ...only Check externally connected devices Optical alarm Rx RU only Check fibre loss of optical link Check optical connectors Clean optical connectors MU Check optical output power of corresponding OTRx...

Страница 41: ...als on the modules to maintain warranty Please keep these guidelines in mind during maintenance The spare parts list consequently contains only units which can be replaced without tuning or soldering...

Страница 42: ...s the instructions in section 6 1 General before starting with the replacement 1 Switch off the Remote Unit Make sure mains is disconnected for the following replacement procedure Then proceed as foll...

Страница 43: ...he earth bonding cable and the fan connector see step 4 Then place the fan unit back into its original position and fasten it tight as shown below 6 Screw the whole fan unit to the cabinet with the fo...

Страница 44: ...ate with the fan unit from the Remote Unit as described in section 6 2 Replacing the Fan Unit steps 1 and 2 3 Use compressed air max 5 bar to blow out the heat sink from back to front 4 In case the di...

Страница 45: ...7 Appendix Manual MF0145AXA doc Manual for ION M17P 19P Advanced Page 45 7 Appendix 7 1 Illustrations figure 7 1 Cabinet drawing...

Страница 46: ...B to 10 dB 7 2 2 Environmental and Safety Specifications Note For detailed information please refer to the Environmental and Safety Specifications leaflet of the supplier related to ETS 300 019 Europe...

Страница 47: ...t of the Remote Unit ION M17P 19P Advanced Designation ID No ION M17P 19P Advanced 7707254 Protective Plug E2000 7160013 Protective Cap E 2000 7158914 Fan Protection Kit 7159097 Fan Unit 7158254 Prote...

Страница 48: ...lug 31 Protective Tube Kit 33 Contact Addresses Customer Support 11 D Declaration of Conformity DoC 10 E External Alarm Inputs Outputs 35 F Fiber Optical Components Installation Cleaning 30 Flange Con...

Страница 49: ......