high speed a frame does not stop immediately and the risks of damaging the sensor are important due 
to the inertia of the motor. 

1.2.3.

 

Building 

The force gauge can be fixed on a frame using M5 screws. 

The length of the screws used should not 

exceed 3mm inside the instrument.

 Contact Andilog if you need more information or if you want an 

adapter to mount the instrument on a rack. 

1.2.4.

 

Precautions during testing 

Most of the tests performed with Andilog Technologies instruments are destructive tests. The hazards 
associated with this type of testing require that our instruments be used by experienced and trained 
operators. Due to the nature and use of the equipment sold by Andilog, the purchaser's acceptance of 
Andilog Technologies' products constitutes acceptance of the risks and damages that may result from 
the use of Andilog's instruments. 

1.2.5.

 

Environmental conditions 

 

Operating temperature : 0 to 35° C  

 

Storage temperature: -20 to 45° C  

 

Relative humidity: 5% to 95%, non-condensing 

 

Maximum altitude of use : 3 000 m 

1.2.6.

 

Warranty 

Subject to the conditions below, Andilog Technologies warrants to the 
purchaser that it will repair or replace at no charge new instruments sold 
subject to normal use and maintenance. This warranty applies if the 
purchaser detects a defect in workmanship or materials during a period of 
two (2) years from the date of shipment. 

The conditions of application are: 

 

ANDILOG Technologies has been notified in writing of the defect 
before the end of the warranty period 

 

Products are shipped to Andilog Technologies with prior agreement 
from Andilog Technologies 

 

All transportation costs are paid by the buyer 

 

The products have been used and maintained under normal conditions of use 

Any repair or replacement made by the seller outside the agreement of Andilog Technologies will void 
the warranty. 

In no event shall Andilog Technologies be liable for any damages, business interruption, or loss of 
production due to the purchase, use, or failure of our products. And this even if Andilog Technologies 
has been informed of the possibility of such damages. 

Содержание CENTOR FIRST II

Страница 1: ...s manual CENTOR FIRST II User s manual CENTOR FIRST II ANDILOG Technologies BP62001 13845 Vitrolles Cedex France COM TEN Industries 6405 49th Street North Pinellas Park FL 33781 USA Site www andilog...

Страница 2: ...4 2 Getting started 6 2 1 Battery charging 6 2 2 Mounting the Accessories 6 2 3 Mounting on a frame 6 3 Using the CENTOR FIRST 7 3 1 Starting up 7 3 2 Extinguishing 8 3 3 Measurement screen 8 3 3 1 D...

Страница 3: ...h a battery charge between 30 and 80 of its autonomy It is recommended to use the original power supply provided by Andilog to charge your instrument The power supply must have the following character...

Страница 4: ...emperature 20 to 45 C Relative humidity 5 to 95 non condensing Maximum altitude of use 3 000 m 1 2 6 Warranty Subject to the conditions below Andilog Technologies warrants to the purchaser that it wil...

Страница 5: ...entation or offers If products are damaged during shipment notify the carrier and Andilog Technologies immediately The warranty is void in case of accident misuse or abuse Calibrations overloaded sens...

Страница 6: ...hould be done by hand without applying much torque Excessive torque or the use of pliers can damage the load cell We recommend that you mount the accessories with the force gauge turned on to ensure t...

Страница 7: ...evice is functional the force gauge displays the measurement screen It then displays 0 N A tare is performed when the device is started If the applied force is greater than 20 of the maximum capacity...

Страница 8: ...n the force gauge is turned off The force gauge will operate with the same settings when it is turned back on unit display order 3 2 Extinguishing To turn off the Centor First II press and hold the bu...

Страница 9: ...on will be preceded by the symbol A force applied in compression will be preceded by the symbol The display order can be changed by pressing the 3 3 1 Do the Zero During tests it is often necessary to...

Страница 10: ...display The Centor First II remembers the display order when it is turned off 3 3 4 Auto off The automatic shutdown saves the battery charge The force gauge is automatically switched off after 15 min...

Страница 11: ...using the on off key My device does not display the measurement screen but an information page with Offset in red If the offset value is greater than 20 the device cannot measure Turn off your device...

Страница 12: ...User s manual CENTOR FIRST II 12 Characteristic Capacity Accuracy 0 25 of capacity Autonomy 3 p m Power supply MicroUSB 5V 1A Net weight 520 g Units N daN kg lb Sensor sampling frequency 1000 Hz...

Отзывы: