User's manual 

CENTOR FIRST II 

 

- 10 - 

The number of decimal points displayed changes according to the unit chosen.  

  

3.3.3.

 

Change the display order 

  

The force gauge detects and stores the maximum in tension and compression. Press the key

 

. The display order of the different values will shift upwards. The top line will then move to the 
bottom. Each press of this key changes the display. The Centor First II remembers the display order 
when it is turned off. 

 

3.3.4.

 

Auto-off  

The automatic shutdown saves the battery charge. The force gauge is automatically switched off 
after 15 minutes without pressing any key. 

  

3.3.5.

 

Maintenance screen 

A long press on the U button displays a maintenance screen. This screen provides information about 
the sensor and its status. 

 

 

 

 

 

 

Sensor capacity 

Number of times the sensor has 
been overloaded 

Maximum force that has been 
applied to the sensor beyond 
the capacity 

0 offset of the sensor 

Factory settings of the sensor 

Содержание CENTOR FIRST II

Страница 1: ...s manual CENTOR FIRST II User s manual CENTOR FIRST II ANDILOG Technologies BP62001 13845 Vitrolles Cedex France COM TEN Industries 6405 49th Street North Pinellas Park FL 33781 USA Site www andilog...

Страница 2: ...4 2 Getting started 6 2 1 Battery charging 6 2 2 Mounting the Accessories 6 2 3 Mounting on a frame 6 3 Using the CENTOR FIRST 7 3 1 Starting up 7 3 2 Extinguishing 8 3 3 Measurement screen 8 3 3 1 D...

Страница 3: ...h a battery charge between 30 and 80 of its autonomy It is recommended to use the original power supply provided by Andilog to charge your instrument The power supply must have the following character...

Страница 4: ...emperature 20 to 45 C Relative humidity 5 to 95 non condensing Maximum altitude of use 3 000 m 1 2 6 Warranty Subject to the conditions below Andilog Technologies warrants to the purchaser that it wil...

Страница 5: ...entation or offers If products are damaged during shipment notify the carrier and Andilog Technologies immediately The warranty is void in case of accident misuse or abuse Calibrations overloaded sens...

Страница 6: ...hould be done by hand without applying much torque Excessive torque or the use of pliers can damage the load cell We recommend that you mount the accessories with the force gauge turned on to ensure t...

Страница 7: ...evice is functional the force gauge displays the measurement screen It then displays 0 N A tare is performed when the device is started If the applied force is greater than 20 of the maximum capacity...

Страница 8: ...n the force gauge is turned off The force gauge will operate with the same settings when it is turned back on unit display order 3 2 Extinguishing To turn off the Centor First II press and hold the bu...

Страница 9: ...on will be preceded by the symbol A force applied in compression will be preceded by the symbol The display order can be changed by pressing the 3 3 1 Do the Zero During tests it is often necessary to...

Страница 10: ...display The Centor First II remembers the display order when it is turned off 3 3 4 Auto off The automatic shutdown saves the battery charge The force gauge is automatically switched off after 15 min...

Страница 11: ...using the on off key My device does not display the measurement screen but an information page with Offset in red If the offset value is greater than 20 the device cannot measure Turn off your device...

Страница 12: ...User s manual CENTOR FIRST II 12 Characteristic Capacity Accuracy 0 25 of capacity Autonomy 3 p m Power supply MicroUSB 5V 1A Net weight 520 g Units N daN kg lb Sensor sampling frequency 1000 Hz...

Отзывы: