SERVICE PARTS

No.

Part Description

Part No.

9

Capacitor, 50MFD, 370VAC, (compressor)

5594

10

Capacitor, 10MFD, 450VAC, Deh, (fan)

5573

11

RH Sensor, Deh

5460

12

Drain Tube + Fittings

5692

13

Compressor Overload Switch

5574

Not Shown

Condensate Pump with Tubing

4856

Alert Light

5818

No.

Part Description

Part No.

1

Filter, 16" x 19" x 1" 

5769

2

Internal Control Board, Deh

5444

3

User Interface Assembly, Deh

5738

4

Door, Filter Access, AA Deh

5571

5

Fan, 130pt Deh, with 10MFD Capacitor

5572

6

Wire Harness, Power, Deh

5454

7

Sensor, Low Temperature, Deh

5455

8

Sensor, High Temperature, Deh

5456

1

11

3

13

12

6

8

7

2

9

10

5

4

90-2041

11

Содержание A130F

Страница 1: ...ications Pool chemicals can damage the dehumidifier 4 Do not use solvents or cleaners on or near the circuit board Chemicals can damage circuit board components 5 Wait 24 hours before running the unit...

Страница 2: ...RATION 8 Using the Dehumidifier Control 8 Using the Model A77 Remote Control 8 TROUBLESHOOTING 9 Table 1 Diagnostic Codes 9 Table 2 Troubleshooting Guide 10 SERVICE PARTS 11 LIMITED WARRANTY 12 SPECIF...

Страница 3: ...rvice access will require the removal of the side panel shown Allow sufficient space for service on this side of the unit Always install the dehumidifier in a condensate pan when locating in or over a...

Страница 4: ...l surface is required to ensure proper drainage from the dehumidifier CONDENSATE PAN CONDENSATE PUMP AND FLOAT SWITCH A condensate pan is recommended when locating in or above a finished space or susp...

Страница 5: ...tighten to secure 4 Restore dehumidifier power There is a delay of three minutes after restoring power before the dehumidifier will respond to the control 5 Go to REMOTE CONTROL on page 6 to configure...

Страница 6: ...r for the installed application Use the UP or DOWN buttons to select items and use MODE to switch to the next set up option To exit installer set up all options must be scrolled through using the MODE...

Страница 7: ...red the dehumidifier and all of the wired components will turn on and off during Installer Test Mode to demonstrate that all are properly operating Installer Test Mode lasts for four 4 minutes If the...

Страница 8: ...he setting the blowers turn off and the display returns to showing the RH setting 4 The dehumidifier will sample again after the number of minutes selected during the Air Sampling portion of the Syste...

Страница 9: ...sensor temperature while also displaying ON Scroll through these values and by using the UP DOWN arrow buttons 7 Record values and call Technical Support Cycle Power E5 High Temperature Thermistor Fai...

Страница 10: ...ty condensate pan If no float switch installed check that the jumper is installed at the float switch terminals on the control board Coil frosting defrost Lack of or reduced airflow Check dehumidifier...

Страница 11: ...5574 Not Shown Condensate Pump with Tubing 4856 Alert Light 5818 No Part Description Part No 1 Filter 16 x 19 x 1 5769 2 Internal Control Board Deh 5444 3 User Interface Assembly Deh 5738 4 Door Filte...

Страница 12: ...LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREA...

Отзывы: