background image

— 7 —

Ø 5.9 in. 

(15 cm) 

22 - 40.9 in. 

(56-104 cm) 

22 in. 

(56 cm) 

8.2 in. 

(21 cm) 

19.6 in. (50 cm) 

2

9

.5 in. (7

5

 cm)  / 35.4 in. (90 cm) 

12 in. (30.5 cm)

10.7 in. (27.3 cm)

14.9 in. (38 cm) 

24.4 in. (62 cm) 

3.1 in. 

(8 cm) 

Range Hood Dimensions

Specifications

Body Design

Stainless Steel

Power Rating

120 V / 60 Hz (cULus Certified)

Total Input Power

405 W (400 W + 2 x 2.5 W) 

Motor Input Power

400 W

Amperage

3.4 A

Speed Control Levels

5 Speeds

Interference Protection

Radio Frequency Interference Protected

Motors 

Single Motor

Control

Touch control panel with LED

Filtration

Baffle filter

Illumination

2 x 2.5 W LED

Fan Type

Single Chamber Quiet

Venting Size

Top, 6 inches (15.3 cm) round

Содержание GCL630

Страница 1: ... GLC636 User Manual Installation Instructions IMPORTANT SAFETY INSTRUCTIONS Carefully read the important information regarding installation safety and maintenance Keep these instructions for future reference MAAN1507 01 2018 08 02 ...

Страница 2: ...ERS Start Here Safety Instructions are on pages 4 and 5 and Operating Instructions are on pages 15 to 17 and 20 Please perform these steps 1 Read the safety instructions 2 Read all instructions in the manual BEFORE operating the range hood 3 Remove all packing materials 4 Installation is to be done by a qualified technician only However the ultimate responsibility for proper installation falls to ...

Страница 3: ...Hood Mounting Bracket 12 Step 8 Installing the Upper Chimney Bracket 12 Step 9 Installing the Glass 12 Step 10 Installing the Damper Flap 13 Step 11 Mount Range Hood onto Wall 13 Step 12 Connect Ductwork 13 Step 13 Install Chimney 14 Step 14 Connect to AC 14 Step 15 Install Filters 15 Operation 16 Lights with three luminance setting auto mode 16 Power 16 Fan with 5 speed setting 16 Timer 16 Mainte...

Страница 4: ...he service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Clean grease laden surfaces frequently To optimize performance and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces cei...

Страница 5: ...UATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have a Class A B C extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it is started 3 The fire department is being called 4 You ...

Страница 6: ...l material Please consult your installation specialist regarding the optimal type of mounting screws and wall anchors to suit your home s construction 4 1 Screws C Installation of Glass Canopy 2 Filter Upper Chimney Lower Chimney Upper Chimney Bracket Lower Chimney Bracket Hood Mounting Bracket 4 1 Chimney Screws E 4 1 Screws Washers D Installation of Glass Canopy Damper flap ...

Страница 7: ...dy Design Stainless Steel Power Rating 120 V 60 Hz cULus Certified Total Input Power 405 W 400 W 2 x 2 5 W Motor Input Power 400 W Amperage 3 4 A Speed Control Levels 5 Speeds Interference Protection Radio Frequency Interference Protected Motors Single Motor Control Touch control panel with LED Filtration Baffle filter Illumination 2 x 2 5 W LED Fan Type Single Chamber Quiet Venting Size Top 6 inc...

Страница 8: ...1 2 115 mm 9 6 7 250 mm 1 5 8 40 mm 3 1 6 81 mm 3 1 6 81 mm 5 8 16 mm 1 1 8 28 mm 11 1 4 287 mm 11 4 5 300 mm 11 4 5 300 mm 8 1 4 211 mm 7 1 2 192 mm Mounting Brackets Upper Chimney Bracket Lower Chimney Bracket Mounting Bracket Hook ...

Страница 9: ...s will reduce the performance of the unit Each elbow is equivalent to 5 to 10 feet 1 5 m to 3 m of straight run Proper size duct work should be 6 in 152 mm in diameter To reach a 9 ft 2 7 m ceiling make sure hood is installed 32 inches 81 2 cm from cooking surface If you have a ceiling greater than 9 ft 2 7 m please visit anconahome com to order a chimney extension If ductwork is already installed...

Страница 10: ...distance of 24 in to 30 in 61 cm to 76 2 cm is recommended between stove top and the bottom of range hood 30 in 76 2 cm minimum is required for gas stove tops 4 Height of hood and duct cover For the most efficient and quiet operation It is recommended that the range hood be vented vertically through the roof through 6 in 15 3 cm or bigger round metal aluminum vent work The size of the vent should ...

Страница 11: ...ve top to hood bottom should be no less than 24 inch for electric cook tops and minimum of 30 inch for gas stove tops and no higher than 30 inch for electric cook tops It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high may be hard to reach and will lose its performance and efficiency If av...

Страница 12: ...t should be positioned flush with the top of the lower chimney See Figure 1 Screw upper and hood mounting brackets in tightly Fig 2 STEP 6 Preparations NOTE To avoid damage to your hood prevent debris from entering the vent opening Determine and mark the center line on the ceiling or wall where the range hood will be installed Make sure there is proper clearance within the ceiling or wall for exha...

Страница 13: ...to seal exterior wall or roof opening around the cap STEP 10 Installing the Damper Flap Fix the damper flap into the damper hole on top of the range hood motor box See Figure 3 If ventilation system is equipped with an external air duct with a different diameter apply a reduction fitting However for maximum performance and safety a 6 in round ducting is recommended Fig 3 STEP 11 Mount Range Hood o...

Страница 14: ...UCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of el...

Страница 15: ... baffles spacers filters oil tunnels oil containers before oil and residue overflow Remove all baffles spacers filters grease tray and oil containers and discard oil and residue Wash with warm soapy water NOTE Stainless steel baffles spacers and oil tunnel are top rack dishwasher safe Dry thoroughly before replacing and follow directions for installation in reverse Filters should be cleaned after ...

Страница 16: ...it 5 shows on screen Indicators are ON xPress once Fan will work at 4th speed Digit 4 shows on screen Indicators are ON yPress second third fourth time Fan will work at 3rd 2nd 1st speed subsequently Digit 3 2 1 shows on screen Indicators are ON UPress fifth time Fan will turn OFF Indicators are OFF Indicator is OFF if lamps are OFF Timer You can only activate the TIMER function when Fan is workin...

Страница 17: ... mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the fan is not spinning at all is stuck or is rattling The fan might be jammed or scraping the bottom due to shipping damage Please contact us immediately The hood is not venting out properly Make sure the distance between the stove top and the bottom of the hood is within 24 in and 30 in 61 and 76 2 cm ...

Страница 18: ...sembly 19 Cover of control box 20 Control board 21 LED puck lights 22 Baffle filter 23 Screw bag Range Hood Assembly Number Part 1 Upper chimney 2 Lower chimney 3 Upper hood mounting bracket 4 Lower hood mounting bracket 5 Hood mounting bracket 6 Power cord 7 Damper Flap 8 Big glass 9 Cover of electronic box 10 Capacitor 11 PCB 12 Base of electronic box 13 Housing assembly 14 15 16 17 18 Panel ass...

Страница 19: ...wer housing 2 Impeller 3 Motor 4 Right blower housing Number Part 1 Junction box cover 2 Capacitor 3 Main PCB board 4 Junction box bottom AC 0V 60Hz 12 Controls PCB Main PCB L N E Capacitor MAX 10 2V 250mA 2 5W Temperature Humidity Sensor CN6 CN5 Optional CN1 CN2 CN4 Motor CN3 CH B CN8 _ LED Pucks _ _ _ ...

Страница 20: ...operating For optimal operation clean range hood and all baffle spacer filter grease tray oil container regularly Regular care will help preserve the appearance of the range hood Cleaning Exterior Surfaces Clean periodically with hot soapy water and clean cotton cloth DO NOT use corrosive or abrasive detergent e g Comet Power Scrub EZ Off oven cleaner or steel wool scoring pads which will scratch ...

Страница 21: ...me com Website www anconahome com Ancona is in association with Mr Appliance for all after sales service calls Please contact their service provider or visit their website Phone 888 998 2011 Website www mrappliance com 2018 Copyright of Ancona Home All rights reserved This material may not be reproduced displayed modified or distributed MAAN1507 01 ...

Страница 22: ... 22 Notes ...