STEP 12
Connect Ductwork
• Attach ductwork to damper. Secure the ductwork with duct tape to make sure joints are secure and air- tight.
• Do not install the duct tape too tightly as this may prevent the damper flaps from opening which will overwork the motor
and cause improper functioning of the unit.
• Fasten all connections with sheet metal screws and tape all joints with certified aluminum or foil tape. Use caulking to
seal exterior wall or roof opening around the cap.
Fig #1
STEP 10
Installing the Damper Flap
• Fix the damper flap into the damper hole on top of the range hood motor box.
(See Figure # 3)
• If ventilation system is equipped with an external air duct with a different
diameter, apply a reduction fitting. However, for maximum performance
and safety, a 6 in. round ducting is recommended.
Fig #3
STEP 11
Mount Range Hood onto Wall
• Hang the range hood on the hooks of the lower mounting bracket. (See Figure # 4)
• Screw the range hood to the wall. (See Figure # 5)
CAUTION - Make certain the range hood is secure before releasing!