![Anco Equipment Batch Pasteurizer Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/anco-equipment/batch-pasteurizer/batch-pasteurizer_manual_2941164005.webp)
Tank Inspection
To ensure each tank is in good working order, Anco Equipment inspects every aspects of our
equipment before we ship our product. We ask all our clients to do the same.
Immediately upon arrival of the equipment, confirm the tank has not been scratched, dented, or
missing any parts during transit. Call Anco Equipment immediately if you find something wrong
with your order.
Prepping Instructions
Cleaning your vat: after the manufacturing and shipping process, it is important to thoroughly
wash and degrease your vat. Please see further in this manual or contact your chemical cleaning
supplier for recommendations.
Prior to tank use: be sure to clean and sanitize the vat, pump, outlet valve, supply lines and spray
balls (if present). If you decide to use a chemical based cleaning process; be sure to follow all
manufacturer’s instruction.
To avoid pitting of your equipment NEVER let highly chlorinated
water stand more than ten minutes.
Boiler Installation Instructions
Please use a licensed boiler technician or licensed Pipe Fitter when installing the tank.
The tanks dimple plated jacket is designed to heat and/or cool with Glycol, a hot water boiler or a
steam boiler system. The jacket is tested and rate for 70 maximum pounds per square inch (PSI).
Low pressure boilers are recommended. If you are using a high pressure boiler confirm with your
state rules and regulations that no additional safety valves or documentation are required
(example: ASME).
A properly sized boiler can have your product at pasteurizing temperature within 25 minutes or
less. You will need a licensed plumber or boiler technician to install your boiler system. There
should be pressure valves installed to protect the tank jacket from reaching more than the
maximum PSI allowed.
Please see further in this manual for proper boiler sizing.
If you are heating with steam; the steam inlet is the top port of jacket on the side. If the tank has
2 or more zones the bottom zone ports are interchangeable. See diagram further in this manual.
If you are heating or cooling with water or Glycol the inlet is the bottom or lowest port of jacket.
If the tank has 2 or more zones, the bottom zone ports are interchangeable. See diagram further
in this manual.
9/25/2018
5
Batch Pasteurizer Overview
Содержание Batch Pasteurizer
Страница 16: ...9 25 2018 16 Figure 1 Figure 2...
Страница 19: ...Ground To be installed by a licensed electrician 19 Anco Electric Air Space Heater...
Страница 20: ...Anco Airspace Heater Element 20...
Страница 23: ...9 25 2018 23 Spray Ball Installation and Maintenance...
Страница 24: ...9 25 2018 24 Spray Ball Specification Sheet...