INTRODUCTION 

RHT-Air

  comes with a high accuracy  and stability sensor to measure 

temperature,  relative  humidity,  and dew point. Because it operates with a 

microprocessor, it can be fully configured through its USB and IEEE 802.15.4 

interfaces. 

DigiConfig

 software enables for all the device resources to be 

configured. 

RHT-Air

 can be configured to display the temperature, the relative humidity 

and the dew point and can display up to two of them simultaneously. 

RHT-Air

 must be connected to an 

AirGate-Modbus

 so that it can access its 

parameters when in operation. 

AirGate-Modbus

 will provide Modbus RTU 

access to its registers over the IEEE 802.15.4 wireless network. 
In addition to battery operation with typical range of 1 year (for an update 

interval higher than 60 seconds and stable connection in an IEEE 802.15.4 

network), 

RHT-Air 

can

 

also be powered by an external source. 

1.1

 

IDENTIFICATION 

The following elements appear in the front part of the device:

 

 

Figure 1 –

 

 

RHT-Air

 main screen 

Communication Indicator (COM)

: It signals that the device is receiving data 

from the Modbus network.

 

 

Button

 

(Programming)

: This button is used to configure the Modbus 

address, the Update Interval and to screen changes. 

Temperature

: Environment temperature measured by the device.  

Relative Humidity

: Relative humidity measured by the device.

 

 

Figure 2 –

 

 RHT-Air 

second screen 

Communication Address

:  Programmed value to identify the Modbus 

network device. Programmable between

1

 and 

246

 
 
 
 
 
 
 
 
 
 
 

2

 

SPECIFICATIONS 

Operating 

temperature 

-10 °C to 70 °C (14 °F to 158 °F) 

Sensor 

measurement 

range 

Temperature: -40 °C to 100 °C (-40 °F to 212 

°F) 
Relative Humidity (RH): 0.0 to 100.0 % RH                                  

(No condensation) 
Dew Point: -40 °C and 100 °C (-40 °F to 212 °F) 

Measurements 

Accuracy 

See 

Figure 3

Note

: It is possible to perform an 

Offset

 

adjustment using the 

DigiConfig

  software to 

reduce the measurement error found. 

Response time 

(Sensor) 

Temperature: Up to 30 s with air movement at 1 

m/s. 

Measurements 

Accuracy 

Humidity: Up to 8 s with air movement at 1 m/s 

(20 to 80% RH). 

Interval between 

updates 

Configurable between 15 seconds and 10 

minutes (600 s). 

Power supply 

Power supply: 12 Vcc to 30 Vcc. 
Consumption < 100 mA. 
Internal battery  (included): Lithium 3.6 Vcc 1/2 

AA 0,80 Ah. 

Omnicell

  manufacturer 

(ER14250HD  model)  or 

EEMB

  manufacturer 

(ER14250M model). 

Estimated battery 

life 

Typical: 1 year - Update interval greater than 60 

seconds. 

Connections 

 

Internal

 

USB Device  (micro-B)  for 

configuration and firmware update.  

 

RP-SMA female connector for antenna 

(included). 

 

M12 connector for external power (cable 

included). 

Communication 

Modbus RTU  about  Wireless

 

IEEE  802.15.4 

protocol (

AirGate-Modbus

 necessary)

Wireless 

 

Maximum transmission power of 25,11 mW 

(14 dBm). 

 

Maximum Range: 500 meters line-of-sight in 

open field. 

 

Data rate: RF 250 Kbps. 

 

Receptor sensibility - 92 dBm. 

 

Operation band: ISM 2.4 GHz. 

 

DSSS Technology (Direct Sequence Spread 

Spectrum). 

 

OQPSK Modulation (Offset Quadrature 

Phase Shift Keying). 

 

15 operation channels. 

 

AES-CBC-128 (Advanced Encryption 

Standard). 

Housing

 

Polycarbonate. 

Protection Index

 

IP40 

Dimensions 

60 x 70 x 35 mm. 
Antenna measurement: 105 mm. 
Sensor measurement: 37,2 mm. 

Weight 

171 grams / 40 grams (cable). 

Configuration 

software 

DigiConfig

  –  Configuration software  for 

Windows. 

Certifications 

CE, FCC, ANATEL (00172-13-07089). 
Contains FCC ID: 2AXVWBAIRR-NOVUSAIR

.

 

Electromagnetic 

compatibility 

EMC: EN61326-1:2006 CISPR11/EN55011, 

EN61000-4-2, EN61000-4-3, EN61000-4-4, 

EN61000-4-6, EN61000-4-8 

Содержание Novus RHT-Air

Страница 1: ...NOVUS AUTOMATION 1 10 RHT Air WIRELESS DEVICE FOR TEMPERATURE RELATIVE HUMIDITY AND DEW POINT INSTRUCTIONS MANUAL V2 0x A...

Страница 2: ...212 F Relative Humidity RH 0 0 to 100 0 RH No condensation Dew Point 40 C and 100 C 40 F to 212 F Measurements Accuracy See Figure 3 Note It is possible to perform an Offset adjustment using the DigiC...

Страница 3: ...one through USB interface Remove the four set screws of the front panel of the RHT Air device taking the necessary precaution not to apply force on the internal connector of the electronic circuit Fig...

Страница 4: ...register When it reaches values below 3 3 V a battery change must be scheduled this register may present a measurement error of up to 5 Note Even when the power is below 100 the device will operate n...

Страница 5: ...y 8 Screen Dew point 7 WIRELESS COMMUNICATION RHT Air has an IEEE 802 15 4 wireless communication to connect to AirGates Modbus that has its firmware updated to a version more recent than V1 23 The fi...

Страница 6: ...z 21 2455 MHz 22 2460 MHz 23 2465 MHz 24 2470 MHz 25 2475 MHz REGISTER 28 LINK QUALITY INDICATOR It serves to inform the quality of the reception link of the connection between the device and the AirG...

Страница 7: ...e Modbus network This address identifies the device on the Modbus network Its configuration may range from 1 and 247 There cannot be more than one piece of device with the same address on the same net...

Страница 8: ...rror value 9999 9999 R W 39 Temperature value C or F 400 1000 R 40 Relative humidity value 0 1000 R 41 Dew point value C or F 400 800 R For the abovementioned table ranges one decimal place should be...

Страница 9: ...the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that...

Страница 10: ...NOVUS AUTOMATION 10 10 11 WARRANTY Warranty conditions are available on our website www novusautomation com warranty...

Отзывы: