The A1101R04C output power changes with ambient temperature. To obtain best possible
range and at the same time maintain certification compliance it is possible to trim the output
power as a function of temperature to maintain an approximate constant output power over
temperature. This can be done by changing the output power according to Table 6. The same
information is provided graphically in Figure 4. Note that the power level mentioned is the power
level one would measure at room temperature (i.e. the power level is in fact not increasing with
temperature, but is kept relatively stable when implementing this feature). If temperature
dependent control is not implemented the user must use the lowest power value for all
temperatures in order to maintain power within certification limits. A breakdown of the
temperature levels is given below for each Duty Cycle operation.
Table 6 Power adjustment for temperature
A graphical view of these levels is also provided in the chart below.
-6.5
-4.5
-2.5
-0.5
1.5
3.5
5.5
7.5
9.5
11.5
-40
-20
0
20
40
60
80
10% Cuty Cycle
M1 - 100% Duty Cycle
M2 - 100% Duty Cycle
M9 - 100% Duty Cycle
M10 - 100% Duty Cycle
M14 - 100% Duty Cycle
M15 - 100% Duty Cycle
All others - 100% Duty Cycle
Figure 4 Output Power over temperature
10 % Duty Cycle
Temp Range (C
o
) All Modulations
M1
M2
M9
M10
M14
M15
All Others
(-40, -20)
0xC9
0x8C
0x2B
0x51
0x8B
0x8B
0x8B
0x53
(-20, 55)
0xC6
0x8C
0x2D
0x60
0x8B
0x89
0x8B
0x40
(55, 85)
0xC5
0x8B
0x66
0x8E
0x89
0x87
0x89
0x50
100 % Duty Cycle