Specifications

Input Voltages

Nominal (ip)

24

48

72

Actual

** 20 – 35

** 40 – 60

** 65 – 90

Input Amps (max)

72.6

36.3

23

Input Fuse

3 x ATC25

2 x ATC20

1 x ATC30

Output Voltages

Nominal (op)

12

24

32

48

Actual

13.6 ± 0.05V

27.2 ± 0.05V

36.3 ± 0.05V

54.4 ± 0.05V

Output Adjustment

± 1.0 Volts

Output Amps (cont)

0 – 60

0 - 40

0 – 30

0 - 20

Output Amps (max)

70

45

34

22.5

Output Crowbar

16.0 ± 0.5 V

32 ± 1.0 V

43.7 ± 1.3 V

63.9 ± 2.0 V

General

Switching Frequency

60 ± 2 KHz

Idle Power

< 10 Watts

Noise on Input

< 50 milli-Volts

Noise on Output

< 50 milli-Volts

Transient Response

< 2V for 50% Surge (Output Amps/2)

Efficiency

> 85 % @ maximum output

Temp. Range

-25 to 40 deg. C @ maximum output

Isolation

Input-Output & Input-Case 1500 Vdc (500 Vdc @ 24 V In),
Output-Case 500 VDC (1500Vdc @ 48 V Out)

Dimensions

19.0 x 14 x 3.5 in / 48.3 x 35.6 x 8.9 cm

Clearance

1 Inch (2.5 cm) all around

Material

Marine Grade Aluminum

Finish

Black Powder Epoxy

Fastenings

18-8 Stainless

Weight

12.2 lb / 5.5 kg

** Actual startup is at 22, 42, or 67Vdc Input, depending on model
*  This is Analytic Systems’ suggested range. Please consult your battery manufacturer for their 

recommendations.

*  Specifications subjects to change without notice.

Содержание VTC1015R Series

Страница 1: ...INSTALLATION OPERATION MANUAL VTC1015R SERIES DC DC VOLTAGE CONVERTER...

Страница 2: ......

Страница 3: ...ery acid to drip on converter when reading gravity or filling battery 7 O P CONNECTION PRECAUTIONS Connect and disconnect DC output connections only after setting I P power switch to the off position...

Страница 4: ...with automatic recovery The output voltage is easily adjusted 1 0 volts above or below the standard output voltage An output overvoltage crowbar circuit protects devices connected to the converter Th...

Страница 5: ...lli Volts Noise on Output 50 milli Volts Transient Response 2V for 50 Surge Output Amps 2 Efficiency 85 maximum output Temp Range 25 to 40 deg C maximum output Isolation Input Output Input Case 1500 V...

Страница 6: ...ble for the correct sizing of the circuit breaker in the distribution panel A ground stud is provided to bond the chassis to local ground to reduce or eliminate EMI OUTPUT CONNECTIONS Two Positive out...

Страница 7: ...h the connector on the back of the unit There are thre terminals N O normally open COM common and N C normally closed Simply connect to either N O or N C and COM to each positive output terminal Conne...

Страница 8: ...ge to drop to maintain the current at the maximum level The input voltage is not high enough for unit to operate LOW INPUT Indicates that the input voltage is below normal because The input voltage is...

Страница 9: ...9...

Страница 10: ...p Components Conformal Dipping and RTV Compound Option w Wide Temperature Operation 40 to 55 C incl Option SM High Voltage Protection on the DC Input Side Option d Paralleling Diodes Option FI Forklif...

Страница 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Отзывы: