IMPORTANT SAFETY INSTRUCTIONS 

 

 

1) 

SAVE THESE INSTRUCTIONS

 — This manual contains important safety and operating 

instructions for this power supply  
 
2) Do not expose this power supply to rain or snow. 
 
3) Use of an attachment not recommended or sold by the power supply manufacturer may 
result in a risk of fire, electric shock, or injury to persons. 
 
4) Do not disassemble this power supply; take it to a qualified serviceman when service or 
repair is required.  Incorrect reassembly may result in a risk of electric shock or fire. 
 
5) To reduce risk of electric shock, unplug this power supply from the outlet before attempting 
any maintenance or cleaning.  Turning off the controls will not reduce this risk. 

 
 

GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

  — The plug must be 

plugged into an outlet that is properly installed and grounded in accordance with al local codes and 
ordinances. 
 

DANGER

 — Never alter AC cord or plug provided — if it will not fit outlet, have proper cord 

installed by a qualified electrician.  Improper connection can result in a risk of an electric shock. 
 

Analytic Systems

 does not recommend the use of the PWS610 Series Power Supplies in life 

support applications where failure or malfunction of this product can be reasonably expected to cause 
failure of the life support device or to significantly affect its safety or effectiveness.  

Analytic Systems

 

does not recommend the use of any of its products in direct patient care. 
 
Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve 
stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, 
blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, 
peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, 
anesthesia ventilators, and infusion pumps as well as any other devices designated as "critical" by the 
U.S. FDA. 

Содержание PWS610 Series

Страница 1: ...PWS610 Series Power Supply Installation Operation Manual ...

Страница 2: ...and ordinances DANGER Never alter AC cord or plug provided if it will not fit outlet have proper cord installed by a qualified electrician Improper connection can result in a risk of an electric shock Analytic Systems does not recommend the use of the PWS610 Series Power Supplies in life support applications where failure or malfunction of this product can be reasonably expected to cause failure o...

Страница 3: ... Input Fuse MDA 12 6 Output Voltages Nominal op 12Vdc 24Vdc 48Vdc Actual 13 6 0 05Vdc 27 2 0 05Vdc 54 4 0 10Vdc Adjust 0 5 Output Crowbar 16 0 0 5 Vdc 32 0 1 0 Vdc 63 9 2 0 Vdc Output Amps cont 40 20 10 Output Amps max 45 25 12 5 Transient Response 1 V for 30A 1 V for 20A 1 V for 9 5A General Input Frequency 45 65 Hz Noise on Input 50 milli Volts Noise on Output 50 milli Volts Efficiency 80 maximu...

Страница 4: ...ovided Connect only one wire to each terminal Ensure that the total average load connected does not exceed the continuous current rating of the unit LOAD SHARE OPTION The units may be configured for load sharing if they are equiped with the optional output isolation diodes To confirm that your unit has these diodes use an ohmmeter to measure the resistance between the two positive output terminals...

Страница 5: ...current into each of the output terminals 1 ammeter and 1 voltmeter allow monitoring of total output current and output voltage TROUBLE SHOOTING This unit provides LED indicators and a buzzer to help diagnose any problems The unit should sound the buzzer to alert you prior to shutting itself down You should immediately check the indicators to determine the cause of the shutdown LOW OUTPUT Indicate...

Страница 6: ... off the unit and move the jumper to the other position on J22 J22 is located next to the relay To change the position of the jumper first turn the unit off and disconnect the unit from both the power and batteries Next turn the unit on for 30 seconds to discharge the capacitors then turn it off again Turn the unit upside down and remove the four screws Remove the cover and locate J22 It will be n...

Страница 7: ...OL A remote control panel may be connected to the power supply using a 9 pin D connector that attaches to the side of the power supply The remote control panel and D connector are part of the remote control option The remote control panel allows the unit to be operated remotely as well as duplicating all the diagnostic indicators and audible alarm ...

Страница 8: ...o remedy the defect after having a reasonable number of opportunities to do so 5 Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone else shall render this warranty void 6 There shall be no warranty for defects or damages caused by faulty installation or hook up abuse or misuse of the equipment including exposure to excessive heat salt or fresh wate...

Отзывы: