IMPORTANT & SAFETY INSTRUCTIONS

1.  SAVE THESE INSTRUCTIONS — This manual contains important safety and operating 

instructions for this power supply 

2.  Do not expose this power supply to rain or snow.
3.  Use of an attachment not recommended or sold by the power supply manufacturer may 

result in a risk of fire, electric shock, or injury to persons.

4.  Do not disassemble this power supply; take it to a qualified serviceman when service or 

repair is required. Incorrect reassembly may result in a risk of electric shock or fire.

5.  To reduce risk of electric shock, unplug this power supply from the outlet before 

attempting any maintenance or cleaning. Turning off the controls will not reduce this risk.

6.  O/P CONNECTION PRECAUTIONS

Connect and disconnect DC output connections only after setting the I/P power switch to 
the off position.

GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS  — The plug must be 
plugged into an outlet that is properly installed and grounded in accordance with al local 
codes and ordinances.

DANGER — Never alter AC cord or plug provided — if it will not fit outlet, have proper cord 
installed by a qualified electrician. Improper connection can result in a risk of an electric 
shock.

Analytic Systems does not recommend the use of the PWS1000R Series Power Supplies in life 
support applications where failure or malfunction of this product can be reasonably expected 
to cause failure of the life support device or to significantly affect its safety or effectiveness. 

Analytic Systems does not recommend the use of any of its products in direct patient care.
Examples of devices considered to be life support devices are neonatal oxygen analyzers, 
nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion 
devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, 
hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators 
for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other 
devices designated as “critical” by the U.S. FDA.

Содержание PWS1000R series

Страница 1: ...kmount Power Supply 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers In...

Страница 2: ...Copyright 2005 2016 Analytic Systems Ware 1993 Ltd Revised May 20 2016...

Страница 3: ...roperly installed and grounded in accordance with al local codes and ordinances DANGER Never alter AC cord or plug provided if it will not fit outlet have proper cord installed by a qualified electric...

Страница 4: ...protects devices connected to the converter The PWS1000R Series Rack Mount Voltage Converter supplies either 12 24 or 48 VDC from a 12 24 or 48 VDC power source Other input or output voltages up to 72...

Страница 5: ...g C maximum output Isolation Input Output Input Case 1500 Vdc Output Case 500 VDC 1500Vdc 48 V Out Dimensions 14 5 x 10 2 x 5 5 in 36 8 x 25 9 x 14 0 cm Clearance 1 Inch 2 5 cm all around Material Mar...

Страница 6: ...connected does not exceed the continuous current rating of the unit For 12Vdc Model Only For 12 Vdc models only the output terminals must be connected as shown below if the load current is greater tha...

Страница 7: ...the diodes are NOT present the terminals will measure the static load resistance Value depends on the output voltage of the unit Assuming the output isolation diodes are present connect one 4 foot pi...

Страница 8: ...DC If you wish to adjust this voltage reach in with a very small flat blade screwdriver to rotate the potentiometer Clockwise increases the output voltage and counter clockwise decreases it Meters The...

Страница 9: ...ceeds the maximum output current rating causing the output voltage to drop to maintain the current at the maximum level The input voltage is not high enough for unit to operate LOW INPUT Indicates tha...

Страница 10: ...10 Page intentionally left blank...

Страница 11: ...ing will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed...

Страница 12: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...

Отзывы: