5
General
Input Frequency
45 - 65 Hz
Noise on Input
< 50 milli-Volts
Noise on Output
< 50 milli-Volts
Transient Response
< 1 V for 50% surge
Efficiency
> 80 % @ maximum output
Temp. Range
-25 to +40 deg. C @ maximum output
Isolation
Input-Output & Input-Case 1500 Vdc
Output-Case 500 VDC (1500Vdc @ 48 V Out)
Isolation
Output-Case 500VDC
Length
14.5 in / 36.8 cm
Width
10.2 in / 29.9 cm
Height
5.5 in / 14.0 cm
Clearance
1 Inch (2.5 cm) all around
Material
Marine Grade Aluminum
Finish
Anodized
Fastenings
18-8 Stainless
Weight
12 lb / 5.5 kg
Designed and manufactured by:
ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way
Delta, BC V4G 1K5 Canada
p. 604.946.9981 f. 604.946.9983
tf. 800.668.3884 US/Canada
www.analyticsystems.com
[email protected] Revised January 2014
* Specifications subjects to change without notice.
Installation
MOUNTING
Mount the unit in a DRY location. Allow at least 4 inches of clearance around the heat sink
fins for adequate cooling.
POWER CONNECTION
The unit is supplied with a 5 foot power cable. This should normally be adequate to connect to
a source of power. If you must extend the power cable be sure to use a 3 conductor grounded
type extension cable. For hard wiring to a source of power, cut off the plug, and strip the wires
as necessary. The wire colours are
110 VAC
220 VAC
Brown - AC Hot
Brown - AC Hot / Phase 1
Blue - AC Neutral
Blue - AC Neutral / Phase 2
Green - Ground
Green/Yellow - Ground