![Analytic Systems BCH10 Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/analytic-systems/bch10-series/bch10-series_installation-and-operation-manual_2940517008.webp)
Mounting
Mount the unit and allow at least 1 inch
of clearance for adequate cooling.
Input and Output Connections
This unit is equipped with a watertight gland
and short 4 conductor pigtail terminated with
a Deutsch DT04-4P connector. The mating
connector is also supplied, but without
cable. The plug pin out is shown in the table
below.
PIN NAME
DESCRIPTION
1
POSITIVE INPUT (red)
2
NEGATIVE INPUT (black)
3
NEGATIVE OUTPUT (black)
4
POSITIVE OUTPUT (orange)
Connect the input pins to the power source, and the output pins to the load, making sure
to observe the correct polarity of the connections. If the input is connected in reverse, the
protection fuse will blow, and must be replaced by the dealer or an electronics technician.
8
4.64
0.21
5.91
2.15
7.0±1.0
orange 4
black 3
1 red
2 black
Installation