Analytic Systems BCH10 Series Скачать руководство пользователя страница 11

11

Limited Warranty

1.  The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free 

from defects in workmanship and materials under normal use and service.

2.  This warranty is in effect for:

a.  3 Years from date of purchase by the end user for standard products offered in our catalog.
b.  2 Years from date of manufacture for non-standard or OEM products
c.  1 Year from date of manufacture for encapsulated products.

3.  Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card 

when returned within 30 days, or

a.  The date of shipment by Analytic Systems, or
b.  The date of manufacture coded in the serial number, or 
c.  From a copy of the original purchase receipt showing the date of purchase by the user.

4.  In case any part of the equipment proves to be defective, the Purchaser should do the following:

a.  Prepare a written statement of the nature of the defect to the best of the Purchasers knowledge, and 

include the date of purchase, the place of purchase, and the Purchasers name, address and telephone 

number.

b.  Call Analytic Systems at 800-668-3884 or 604-946-9981 and request a return material authorization 

number (RMA).

c.  Return the defective part or unit along with the statement at the Purchasers expense to the Warrantor; 

Analytic Systems Ware (1993) Ltd., 8128 River Way, Delta, B.C., V4G 1K5, Canada.

5.  If upon the Warrantor’s examination the defect proves to be the result of defective material or workmanship, 

the equipment will be repaired or replaced at the Warrantor’s option without charge, and returned to the 

Purchaser at the Warrantor’s expense by the most economical means. Requests for a different method of return 

or special handling will incur additional charges and are the responsibility of the Purchaser.

6.  Analytic Systems reserves the right to void the warranty if:

a.  Labels, identification marks or serial numbers are removed or altered in any way.
b.  Our invoice is unpaid.
c.  The defect is the result of misuse, neglect, improper installation, environmental conditions,  non-

authorized repair, alteration or accident.

7.  No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the 

defect after having a reasonable number of opportunities to do so.

8.  Only the Warrantor shall perform warranty service. Any attempt to remedy the defect by anyone else shall 

render this warranty void.

9.  There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of 

the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for 

equipment specifically stated to be waterproof.

10. No other express warranty is hereby given and there are no warranties that extend beyond those described 

herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied 

warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a 

particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives.

11. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and 

representatives for injury to any person or persons, or damage to property, or loss of income or profit, or any 

other consequential or resulting damage which may be claimed to have been incurred through the use or sale of 

the equipment, including any possible failure of malfunction of the equipment, or part thereof.

12. The Warrantor assumes no liability for incidental or consequential damages of any kind

Содержание BCH10 Series

Страница 1: ...INSTALLATION OPERATION MANUAL BCH10W BCH10Y BATTERY CHARGER...

Страница 2: ...attery charger 6 Never allow battery acid to drip on the battery charger BATTERY SAFETY 1 WARNING RISK OF EXPLOSIVE GASES i WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE E...

Страница 3: ...ng in contact with eyes xiii Study all the battery manufacturer s specific precautions such as removing or not removing cell caps while charging and recommended rates of charge Medical Equipment Notic...

Страница 4: ...nings and advisories Table of Contents Description Overview of product Main Parts Operation instructions Mounting Instructions Connection instructions Options Faults Specifications Warranty Revised Se...

Страница 5: ...nd is designed to be water resistant to IP66 The BCH10Y is an upgraded version with the same connections that is individually tested to meet IP67 The all surface mount high frequency design offers hig...

Страница 6: ...6 Main Parts Front Panel 1 Deutsch DT04 4P Input Output connector on pigtail 2 Input Power Good LED 3 Charging LED 1 2 3...

Страница 7: ...fter a period of time which may be minutes to hours the batteries will reach the float voltage and the charging current will begin to drop When the current falls to 10 of the rated charging current th...

Страница 8: ...ug pin out is shown in the table below PIN NAME DESCRIPTION 1 POSITIVE INPUT red 2 NEGATIVE INPUT black 3 NEGATIVE OUTPUT black 4 POSITIVE OUTPUT orange Connect the input pins to the power source and...

Страница 9: ...anding 1 meter immersion for 30 minutes with no ingress of moisture This unit provides LED indicators to help diagnose any problems CHARGING Indicates that the battery charger is charging the batterie...

Страница 10: ...shelf mount Connections BCHW Deutsch DT04 4P on 15cm Pigtail Mating Connector Included Shock and Vibration Designed to meet MIL STD 810G Environmental and Safety Operating Temperature Range 40 C to 55...

Страница 11: ...ing will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed...

Страница 12: ...SIGNED AND MANUFACTURED BY 800 668 3884 604 946 9983 sales analyticsystems com www AnalyticSystems com 8128 River Way Delta BC V4G 1K5 Canada Battery Chargers Inverters Power Supplies Voltage Converte...

Отзывы: