Limited Warranty

1.  The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free 

from defects in workmanship and materials under normal use and service.

2.  This warranty is in effect for:

a.  3 Years from date of purchase by the end user for standard products offered in our catalog.
b.  2 Years from date of manufacture for non-standard or OEM products
c.  1 Year from date of manufacture for encapsulated products.

3.  Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card 

when returned within 30 days, or

a.  The date of shipment by Analytic Systems, or
b.  The date of manufacture coded in the serial number, or 
c.  From a copy of the original purchase receipt showing the date of purchase by the user.

4.  In case any part of the equipment proves to be defective, the Purchaser should do the following:

a.  Prepare a written statement of the nature of the defect to the best of the Purchasers knowledge, and 

include the date of purchase, the place of purchase, and the Purchasers name, address and telephone 

number.

b.  Call Analytic Systems at 800-668-3884 or 604-946-9981 and request a return material authorization 

number (RMA).

c.  Return the defective part or unit along with the statement at the Purchasers expense to the Warrantor; 

Analytic Systems Ware (1993) Ltd., 8128 River Way, Delta, B.C., V4G 1K5, Canada.

5.  If upon the Warrantor’s examination the defect proves to be the result of defective material or workmanship, 

the equipment will be repaired or replaced at the Warrantor’s option without charge, and returned to the 

Purchaser at the Warrantor’s expense by the most economical means. Requests for a different method of return 

or special handling will incur additional charges and are the responsibility of the Purchaser.

6.  Analytic Systems reserves the right to void the warranty if:

a.  Labels, identification marks or serial numbers are removed or altered in any way.
b.  Our invoice is unpaid.
c.  The defect is the result of misuse, neglect, improper installation, environmental conditions,  non-autho-

rized repair, alteration or accident.

7.  No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the 

defect after having a reasonable number of opportunities to do so.

8.  Only the Warrantor shall perform warranty service. Any attempt to remedy the defect by anyone else shall 

render this warranty void.

9.  There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of 

the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for 

equipment specifically stated to be waterproof.

10. No other express warranty is hereby given and there are no warranties that extend beyond those described 

herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied 

warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a 

particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives.

11. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and rep-

resentatives for injury to any person or persons, or damage to property, or loss of income or profit, or any other 

consequential or resulting damage which may be claimed to have been incurred through the use or sale of the 

equipment, including any possible failure of malfunction of the equipment, or part thereof.

12. The Warrantor assumes no liability for incidental or consequential damages of any kind

Содержание BCDi320

Страница 1: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters...

Страница 2: ...Copyright 2005 2019 Analytic Systems Ware 1993 Ltd Revised May 29 2019...

Страница 3: ...not reduce this risk 5 Never place battery charger directly above battery gases from battery will corrode and damage battery charger 6 Never allow battery acid to drip on the battery charger BATTERY...

Страница 4: ...f acid enters eye immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately v NEVER smoke or allow a spark or flame in the vicinity of a battery vi Be...

Страница 5: ...id batteries Flooded traditional Lead Acid AGM Absorbed Glass Mat Lead Acid and Gel or VRLA Valve Regulated Lead Acid A fourth profile pre set for a typical Lithium Ion battery is also avail able Thes...

Страница 6: ...l Rear Panel 10 2 3 4 6 End of Charge Switch 7 Equalize Start Button 8 Stage Select Switch 9 Battery Output Connection 2x Phoenix VDFK Terminal Block Connetions Red Positive Black Negative 10 Chassis...

Страница 7: ...ode the unit s functionality is changed in the following ways The DC Battery Outputs will be live regardless of whether or not a battery is detected The End of Charge Switch and Stage Select Switch ha...

Страница 8: ...ack to Charger mode even if it is turned off 5 To change the unit back to Battery Charger mode press and hold the Power Button until you hear one beep POWER SUPPLY MODE In Power Supply mode the LED in...

Страница 9: ...inal Black Input Lead Negative DC Terminal Normally these leads should be adequate to connect to the DC power source however if you must extend the leads be sure to Use the smallest extension length p...

Страница 10: ...t connect the battery in the reverse polarity This will activate the reverse connection protection which will blow the output fuses inside the unit in order to protect the device The unit will be inop...

Страница 11: ...Press the Program PRG button to cycle through the parameters you can program The pa rameter which you programming can be determined by which bottom row LED is blinking If the DEV LED is blinking you a...

Страница 12: ...be more than what is optimal or recommended Refer to your battery manufacturer s documentation to determine its maximum safe charg ing current If needed the unit s maximum charging current can be red...

Страница 13: ...BLINKING DEFAULT COLD 5 C 41 F I P POL TEMP 25 DEV CH 75 SVC FLT LO V BAT 50 EQ PS DEFAULT AUTO I P POL TEMP 25 DEV CH 75 SVC FLT LO V BAT 50 EQ PS DEFAULT HOT 38 C 105 F I P POL TEMP 25 DEV CH 75 SVC...

Страница 14: ...n like this until it detects that the battery voltage has dropped 90 of the rated voltage It will then initiate a new recharge cycle The charger will also initiate a new recharge cycle if power to the...

Страница 15: ...ts Float Constant Volts Time Three Stage Charge Volts Amps Charging Profiles This unit has both two stage and three stage charging capability You can choose which charg ing profile is used during oper...

Страница 16: ...cycle Failure to do so can result in severe damage to the battery TO PERFORM AN EQUALIZE CYCLE 1 Connect the battery temperature sensor to the unit and install the sensor at the battery as indicated i...

Страница 17: ...the battery and wall of the battery platform so it sits flush Place the battery so it is sitting on top of the sensor to hold it in place Apply a small amount of silicone RTV sealant to the sensor and...

Страница 18: ...ce or absence of charging voltage on the output and is independent of the microprocessor If the charger is producing voltage on the output the normally closed contact will be closed and there will be...

Страница 19: ...ed that the input voltage has dropped below the minimum level needed for normal operation The charger will shut off and wait for the voltage to recover BATTERY OVERTEMP I P POL TEMP 25 DEV CH 75 SVC F...

Страница 20: ...ge drops below 85 of nominal ie 10V for a 12V charger the charger will show this display until the battery voltage exceeds 85 of nominal BATTERY FAILED I P POL TEMP 25 DEV CH 75 SVC FLT LO V BAT 50 EQ...

Страница 21: ...3rd phases of a recharge cycle where the battery voltage is maintained at a constant level ABSORPTION The first Constant Voltage stage in a 3 stage charging algorithm where the battery is maintained a...

Страница 22: ...by Charger Firmware Mechanical Dimensions 9 5 in 24 1 cm Long x 8 0 in 20 3 cm Wide x 3 25 in 8 3 cm High Clearance 2 0 in 5 0 cm all around Weight 6 2 lb 2 8 kg Material and Finish Marine Grade Black...

Страница 23: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 24: ...ms com support warranty registration DESIGNED AND MANUFACTURED BY 800 668 3884 604 946 9983 sales analyticsystems com www AnalyticSystems com 8128 River Way Delta BC V4G 1K5 Canada Battery Chargers In...