If acid enters eye, immediately flood eye with running cold water for at least 10 

minutes and get medical attention immediately.

v.  NEVER smoke or allow a spark or flame in vicinity of battery or engine.
vi.  Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark 

or short-circuit battery or other electrical part that may cause explosion.

vii.  Remove personal metal items such as rings, bracelets, necklaces, and watches when 

working with a lead-acid battery. A lead-acid battery can produce a short-circuit cur-

rent high enough to weld a ring or the like to metal, causing a severe burn.

viii.  NEVER charge a frozen battery.
ix.  If necessary to remove battery from service, always remove grounded terminal from 

battery first. Make sure all accessories in the vessels are off, so as not to cause an 

arc.

x.  Be sure area around battery is well ventilated.
xi.  Clean battery terminals. Be careful to keep corrosion from coming in contact with 

eyes.

xii.  Study all battery manufacturer’s specific precautions such as removing or not remov-

ing cell caps while charging and recommended rates of charge.

xiii.  Add distilled water in each cell until battery acid reaches level specified by battery 

manufacturer. This helps purge excessive gas from cells. Do not overfill. For a battery 

without cell caps, carefully follow manufacturer’s recharging instructions.

3.  BATTERY CHARGER LOCATION

i.  Never place battery charger directly above battery; gases from battery will corrode 

and damage battery charger.

ii.  Never allow battery acid to drip on battery charger when reading gravity or filling 

battery.

Analytic Systems does not recommend the use of the BCD615R Series DC Battery Chargers 

in life support applications where failure or malfunction of this product can be reasonably 

expected to cause failure of the life support device or to significantly affect its safety or 

effectiveness. Analytic Systems does not recommend the use of any of its products in direct 

patient care.

Examples of devices considered to be life support devices are neonatal oxygen analyzers, 

nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfu-

sion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, 

hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators 

for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other 

devices designated as “critical” by the U.S. FDA.

Содержание BCD615R

Страница 1: ...ies Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers In...

Страница 2: ...Copyright 2005 2014 Analytic Systems Ware 1993 Ltd...

Страница 3: ...ng battery 8 O P CONNECTION PRECAUTIONS Connect and disconnect DC output connections only after setting I P power switch to the off position GENERAL WARNING 1 WARNING RISK OF EXPLOSIVE GASES i WORKING...

Страница 4: ...er in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without cell caps carefully follow manufactur...

Страница 5: ...2 1 Input Fuse ATC 15 x 3 25 x 1 25 x 1 Output Voltages Nominal op 12 24 48 Output Volts DC 13 6 0 05 27 2 0 05 54 4 0 05 Absorption Voltage Vdc 14 4 28 8 57 6 Charging Amps 40 20 10 Absorption to Flo...

Страница 6: ...e correct sizing of the circuit breaker in the distribution panel If the power is connected in reverse the input fuses will blow Remove the top cover of the charger to replace them Red Positive Black...

Страница 7: ...making the connections to the battery bank s The charger may be hooked to 1 or 2 battery banks Hook up the battery bank s as shown below If you are hooking up 2 battery banks keep in mind that they M...

Страница 8: ...ability to keep the battery at optimal charge 100 75 50 25 0 Bulk Constant Current Float Constant Volts Time Two Stage Charge Volts Amps 100 75 50 25 0 Bulk Constant Current Absorption Constant Volts...

Страница 9: ...or deep cycle lead acid VLRA or gel type batteries The charger includes a user selectable equalize function The purpose of the equalize func tion is to deliberately overcharge the battery to force any...

Страница 10: ...cators to determine the cause of the shutdown CHARGING Indicates that the battery charger is charging the batteries If the LED is not on the batteries may be fully charged and the charger is supplying...

Страница 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 12: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...

Отзывы: