Analytic Systems BCD615R Скачать руководство пользователя страница 3

3

IMPORTANT & SAFETY INSTRUCTIONS

1.  SAVE THESE INSTRUCTIONS — This manual contains important safety and operating 

instructions for the battery charger.

2.  CAUTION — To reduce risk of injury, charge only lead acid or sealed gel cell type 

rechargeable batteries. Other types of batteries may burst causing personal injury and 

damage.

3.  Do not expose battery charger to rain or snow.
4.  Use of an attachment not recommended or sold by the battery charger manufacturer may 

result in a risk of fire, electric shock, or injury to persons.

5.  Do not disassemble battery charger; take it to a qualified serviceman when service or 

repair is required. Incorrect reassembly may result in a risk of electric shock or fire.

6.  To reduce risk of electric shock, disconnect battery charger from batteries or other DC 

supply before attempting any maintenance or cleaning. Turning off controls will not 

reduce this risk.

7.  Never allow battery acid to drip on battery charger when reading gravity or filling battery.
8.  O/P CONNECTION PRECAUTIONS

Connect and disconnect DC output connections only after setting I/P power switch to the 

off position.

GENERAL WARNING

1.  WARNING — RISK OF EXPLOSIVE GASES.

i.  WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES 

GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS 

REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING 

EQUIPMENT IN THE VICINITY OF THE BATTERY, YOU READ THIS MANUAL AND FOL-

LOW THE INSTRUCTIONS EXACTLY.

ii.  To reduce risk of battery explosion, follow these instructions and those published by 

battery manufacturer and manufacturer of any equipment you intend to use in vicin-

ity of battery. Review cautionary marking on these products and on engine.

2.  PERSONAL PRECAUTIONS

i.  Someone should be within range of your voice or close enough to come to your aid 

when you work near a lead-acid battery.

ii.  Have plenty of fresh water and soap nearby in case battery acid contacts skin, cloth-

ing, or eyes.

iii.  Wear complete eye protection and clothing protection. Avoid touching eyes while 

working near battery.

iv.  If battery acid contacts skin or clothing, wash immediately with soap and water. 

Содержание BCD615R

Страница 1: ...ies Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers In...

Страница 2: ...Copyright 2005 2014 Analytic Systems Ware 1993 Ltd...

Страница 3: ...ng battery 8 O P CONNECTION PRECAUTIONS Connect and disconnect DC output connections only after setting I P power switch to the off position GENERAL WARNING 1 WARNING RISK OF EXPLOSIVE GASES i WORKING...

Страница 4: ...er in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without cell caps carefully follow manufactur...

Страница 5: ...2 1 Input Fuse ATC 15 x 3 25 x 1 25 x 1 Output Voltages Nominal op 12 24 48 Output Volts DC 13 6 0 05 27 2 0 05 54 4 0 05 Absorption Voltage Vdc 14 4 28 8 57 6 Charging Amps 40 20 10 Absorption to Flo...

Страница 6: ...e correct sizing of the circuit breaker in the distribution panel If the power is connected in reverse the input fuses will blow Remove the top cover of the charger to replace them Red Positive Black...

Страница 7: ...making the connections to the battery bank s The charger may be hooked to 1 or 2 battery banks Hook up the battery bank s as shown below If you are hooking up 2 battery banks keep in mind that they M...

Страница 8: ...ability to keep the battery at optimal charge 100 75 50 25 0 Bulk Constant Current Float Constant Volts Time Two Stage Charge Volts Amps 100 75 50 25 0 Bulk Constant Current Absorption Constant Volts...

Страница 9: ...or deep cycle lead acid VLRA or gel type batteries The charger includes a user selectable equalize function The purpose of the equalize func tion is to deliberately overcharge the battery to force any...

Страница 10: ...cators to determine the cause of the shutdown CHARGING Indicates that the battery charger is charging the batteries If the LED is not on the batteries may be fully charged and the charger is supplying...

Страница 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 12: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...

Отзывы: