12
13
Troubleshooting
In the event that your unit is not operating normally, the table below can be used to
troubleshoot the cause of the problem and recommend the next course of action.
Issue:
The output fuse(s) immediately blow when the unit is turned ON.
Check:
The battery is likely connected in reverse polarity and the output fuses have
blown to protect the unit from erroneous current. To replace the output fuses,
see
Fuse Replacement.
Issue:
The input fuse has blown during operation
Check:
The design of the unit makes it impossible to supply an input over current
by conventional means. Usually the input fuses blowing means there is an
internal component failure and the unit must be returned for repair.
Issue:
The unit keeps turning OFF.
Check:
Check the temperature of the unit. If the unit is running above its operating
temperature range, its thermal derating may cause it to turn OFF. If the unit
feels significantly hot, improve the air circulation around the unit.
Issue:
The unit will not turn ON.
Check:
Check the input AC power source, make sure it is supplying a suitable voltage
and current to the unit. Check the input connections, make sure they are
connected and undamaged. If there are no issues with the input, the cause is
likely an internal component failure and,the unit must be returned for repair.