Mounting
Mount the unit in a WELL VENTILATED and DRY area with at least one inch (2.54 cm) of clear-
ance around the extruded vents. The unit should be mounted on a vertical surface with the
drip shield facing upward as shown below.
Installation
DC Output Connection
This unit is equipped with two sets of Phoenix VDFK block connectors to serve separate DC
output connections. Connect the batteries to this connection using an appropriate gauge of
wire for the current (see
Specifications
for more information). These connections are wired as
follows:
RED:
Positive Battery Terminal
BLACK: Negative Battery Terminal
These connections can be used to charge up to two battery banks simultaneously. If charging
a single battery, connect the positive terminal of that battery to
both
positive DC outputs, this
will reduce strain on the connection.
AC Input Connection
This unit is equipped with a 3-pin Bulgin AC Inlet (6.3mm) Tab Flange Mount to serve as an AC
input connection. Your unit is supplied with an IEC320 cable for connection to an AC power
source, if the supplied cable does not fit your AC receptacle, any other IEC320 cable can be
used.