background image

SYNC SOURCE 

-and syncing to MIDI 

The sequencer can be clocked from three different sources; 

LFO 

Internal LFO becomes the clock source. 

NOTE0 (MIDI SYNC) 

MIDI  Note  000  is  used  to  step  /  clock  the  sequencer.  Each  time  that  note  us  received 
the sequencer will clock one step.  

This  is  the  best  way  to  sync  with  your  DAW,  since  you  can  program  a  string  of  notes 
however you wish: 

16ths 

8ths 

Some rhythmic pattern. 

It  also  allows  you  to  stop  (mute)  the  sequencer  mid-Song,  and  restart  at  will. Also  to 
change the clock pattern, like half the speed, for example - all things you cannot do with 
MIDI Sync. 

EXT 

If a clock signal or LFO is fed into the EXT socket on the rear panel then that becomes 
the source. 

STOP 

Stops the sequencer! 

Analogue Solutions  2021 02

Содержание Leipzig-v3

Страница 1: ...Leipzig v3 User Manual LEIPZIG 3 U S E R M A N U A L Analogue Solutions 2021 02...

Страница 2: ...y to enable many years of superb sounds There are many modulation choices on the rotary select switches All signal choices have been carefully chosen Leipzig was designed by a musician of electronic m...

Страница 3: ...Leipzig v3 User Manual Analogue Solutions 2021 02...

Страница 4: ...Option to overdrive the mixer and filter Plenty of modulation routing possibilities Versatile analogue step sequencer with plenty of clocking options 16 step note sequencer with transpose feature Use...

Страница 5: ...mountable Sound wise it is the same it retains that wonderful angry pure analogue sounds the previous version had We kept the sound the same it s what people love we just added some useful new featur...

Страница 6: ...nique features This manual does not aim to teach you the principles of analogue synthesis and assumes you have prior knowledge of analogue synths and their use What this manual does is list the functi...

Страница 7: ...ion or electric shock Do not excessively bend or twist the adaptor cable Doing so may damage the cable Damaged cables could cause a malfunction a shock or fire hazard Do not allow any small parts like...

Страница 8: ...sk to small children Always place them out of reach Never place objects on top of the unit Never handle the unit the AC adaptor or any cables with wet or moist hands Before cleaning the unit disconnec...

Страница 9: ...Afterwards be sure to wipe the unit dry thoroughly with a dry cloth Be sure to disconnect the AC adaptor before any cleaning Never use benzene thinners alcohol or other such chemicals and solvents to...

Страница 10: ...Leipzig v3 User Manual MAKING CONNECTIONS FRONT PANEL REAR PANEL 10...

Страница 11: ...O to start the sequencer Slowly increase the level on your mixer to a suitable level Note you will have to adjust other controls on Leipzig to get a sound like VOLUME VCO Levels Filter CUTOFF Many set...

Страница 12: ...Leipzig v3 User Manual TOUR OF THE CONTROLS VCO VOLTAGE CONTROL OSCILLATORS The two VCOs are almost identical but VCO1 has a manual Pulse Width control and VCO2 has a Sync feature 12...

Страница 13: ...alling in pitch to the new note The Glide knob changes the rate time it takes to reach the new note MANUAL PULSE WIDTH VCO1 ONLY This changes the pulse width duty cycle of the square wave Basically tu...

Страница 14: ...e pitches of VCO1 and VCO2 to find a setting that works best MIDI PITCH VCO 2 This switch disconnects the Pitch control of VCO2 from MIDI so it will no longer respond to MIDI note commands It becomes...

Страница 15: ...ive more NOISE EXTERNAL TOGGLE SWITCH The switch selects either white noise or the signal if any patched into the EXT socket SUB VCO1 This is the sub oscillator taken from VCO1 It s one octave down an...

Страница 16: ...RESONANCE Sometimes called Q or Emphasis on other synths This changes the Q or feedback at the cutoff frequency In simple terms the squigyness of the sound KEY TRACK This control routes pitch CV to th...

Страница 17: ...LFO RATE This control sets the speed of the LFO MODULATION This section selects and routes various modulation signals to the VCO and VCF circuits The three rotary switches select the modulation source...

Страница 18: ...entical so only one will be described ATTACK This controls how low the EG takes to reach maximum level once triggered DECAY After reaching maximum level following the Attach stage Decay sets the time...

Страница 19: ...re four choices available on the rotary switch MODE EG1 EG2 Normally used to contour the volume GATE The VCA opens and closes with no gradual attack or decay much like an organ THRU This holds the VCA...

Страница 20: ...headphone socket The volume range is quite wide to accommodate a wider range of headphones with differing impedances So with some headphones full level would be really too loud So start with the volu...

Страница 21: ...Gate MIDI Note on off used to trigger the envelopes or clock the sequencer Velocity CV this is a modulation CV It is controlled by MIDI velocity and used to modulate the filter cut off PROGRAM This bu...

Страница 22: ...t off It is fantastic as a modulation source It can also be used to create simple melodies that can be transposed with your MIDI keyboard It can also be used as a simple waveform generator and then us...

Страница 23: ...one step This is the best way to sync with your DAW since you can program a string of notes however you wish 16ths 8ths Some rhythmic pattern It also allows you to stop mute the sequencer mid Song an...

Страница 24: ...Leipzig v3 User Manual STEP The step button allows you to manually step the sequencer STEP CV KNOBS 1 8 These adjust the CV level for each step 24...

Страница 25: ...ne the VCO1 and VCO2 mod level pots by ear so that both VCOs are playing in unison However by adjusting them differently you can make them seem to play separate melodies or in combination with other s...

Страница 26: ...te switches are set VCO2 wave set to Square RHYthm switch set on down VCO2 will only sound when the Rhythm LED is lit This in conjunction with VCO1 which will always play on every sequencer step will...

Страница 27: ...loop Each time a clock is received as set by the Sync Source rotary switch the next note in the 16 step loop is played It is always locked in sync with the analogue sequencer New notes can be entered...

Страница 28: ...precisely calibrated to 1V Octave since it s not necessary however it is pretty close should for some odd reason you want to use a MIDI converter Remember it has one built in VCO2 PITCH MOD Same as ab...

Страница 29: ...the clock signal selected to clock the sequencer It can be Thru ed onto another device so all sync together LFO TRIANGLE AND SQUARE LFO signal outputs EG 1 2 EG 1 and 2 signal outputs SEQ CV This is t...

Страница 30: ...Leipzig v3 User Manual SPECIFICATION Leipzig v3 Power 18V regulated DC 500mA or higher Power plug 2 1mm Centre positive Weight mass Approx 3Kg Size 432 x 262 x 63 mm WxDxH 30...

Страница 31: ...alteration misuse accident neglect such as extremes of temperature and or moisture or to wear resulting from normal use At the sole discretion of Analogue Solutions the warranty is deemed to be void s...