EVAL-SSM3515Z User Guide
UG-580
Rev. A | Page 7 of 19
11.
window, under the
File
menu, click
New Project
12.
From the
Tree Toolbox
, under
Processors (ICs/DSPs)
,
drag the
SSM3515
block to the schematic page; and from
under
Communication Channel
, drag the
USBi
block
onto the schematic page. Using the mouse, connect the two
as shown in Figure 5.
13.
If the I
2
C communication failure message appears, as
shown in Figure 4, the board is not set up correctly.
a.
If the yellow light on USBi flickers, disconnect and try
reconnecting the USB connector from the USBi board.
b.
Check if the SCL/SDA signal lines at J2-2 and J3-2 are
pulled to high.
c.
Check the 1.8 V IOVDD on P1-2.
If the error persists, further debug for I
2
C is required before
proceeding further.
1
1
691
-1
05
Figure 4. I
2
C Communication Failure Message
1
16
91-
1
04
PROCESSERS
(ICs/DSPs)
COMMUNICATION
CHANNEL
IC1 TAB
Figure 5. New Project Setup