FEATURES 

Flexible inertial sensor evaluation platform 

Single main board operates with interchangeable satellite 

boards 

Separates device under test (DUT) from the larger main 

board for accurate environmental testing 

Continuous stream to file data recording 
Standard USB cable for power and communications 
PC-based graphical user interface (GUI) 
Fast, easy installation 

DOCUMENTS NEEDED 

ADXRS290

 data sheet 

EQUIPMENT NEEDED 

Evaluation kit contents 

Main (mother) board and satellite board 
A USB A to mini-B cable 

An 18-inch, 20-pin ribbon cable 

PC running Windows® 
USB 2.0 port 
Required software 

ISEB USB Driver

 

ISEB Run-Time Engine

 

ADXRS290 Evaluation GUI Installer

 

Design and integration files

 

Schematics and layout files

 

TYPICAL SETUP FOR THE INERTIAL SENSOR 

EVALUATION SYSTEM 

1

28

36-

001

 

Figure 1. 

 

GENERAL DESCRIPTION 

The 

i

MEMS® 

ADXRS290

 inertial sensor evaluation system is an 

easy-to-use evaluation tool targeting bench or desktop 
characterization of Analog Devices, Inc., inertial sensor products. 
The 

EVAL-ADXRS290Z-M

 system contains the inertial sensor 

evaluation board (ISEB) and the 

EVAL-ADXRS290Z-S

 satellite 

board. In addition, a USB A to mini-B cable is included to connect 
the ISEB to a PC, and an 18-inch, 20-pin ribbon cable is included 
to connect the ISEB to the satellite board. The USB connection 
provides both communications and power to the board. The 
ribbon cable allows users to easily manipulate the satellite board 
for testing or to be separately placed into an environmental 
chamber for temperature or humidity testing. 

Separate the boards to mitigate corruption of data due to the 
temperature and humidity effects of other components. 

The ISEB is a universal main board and is used with various 
satellite boards of Analog Devices inertial sensors, including 
accelerometers and gyroscopes. The different products are 
evaluated by means of separate GUIs that are customized for 
performance and characterization measurements relevant to the 
inertial sensor being evaluated. Different shunt resistors are 
used to detect power consumption because the power consumption 
of the gyroscope is relatively high compared to that of the acceler-
ometers. The differences between the 

ADXRS290Z-M

 and other  

-M devices, such as 

ADXL345Z-M

 or 

ADXL362Z-M

, are only 

in the circuit used to detect power consumption. 

Full details about the parts are available in the 

ADXRS290

 data 

sheet, which should be consulted when using the 

EVAL-

ADXRS290Z-M

 

Содержание EVAL-ADXRS290Z-M

Страница 1: ...log Devices Inc inertial sensor products The EVAL ADXRS290Z M system contains the inertial sensor evaluation board ISEB and the EVAL ADXRS290Z S satellite board In addition a USB A to mini B cable is included to connect the ISEB to a PC and an 18 inch 20 pin ribbon cable is included to connect the ISEB to the satellite board The USB connection provides both communications and power to the board Th...

Страница 2: ...ion History 2 Getting Started 3 Software Installation Procedures 3 Evaluation Board Hardware Setup Procedures 7 Evaluation Board Hardware 7 Power Supplies 7 Jumper Settings 7 Evaluation Board Circuitry 7 How to Use the Software for Testing 8 Getting Started 8 Configuration Tab 9 Real Time Data Tab 10 Noise Tab 11 Power Consumption Tab 12 Temperature Tab 13 REVISION HISTORY 1 15 Revision 0 Initial ...

Страница 3: ...B Drivers The USB driver supports Windows 7 and its previous operating systems To install the USB drivers follow these steps 1 Execute the ADI_ISEB_USB_Drivers exe file located in ftp ftp analog com pub iMEMS_Sensor_Eval ISEB_USB_ Driver 2 Follow the on screen instructions to install the drivers 3 Click Continue Anyway when prompted that the drivers are not tested After the previous steps are comp...

Страница 4: ...nsor Evaluation System COM4 is listed with an assigned COM port number in parenthesis see Figure 6 12836 006 Figure 6 Device Manager Showing the COM Port Number 4 Note the COM port number for future use Installing the Latest ISEB Firmware The latest ISEB firmware is found at ftp ftp analog com pub iMEMS_Sensor_Eval To use the ISEB evaluation hardware flash the firmware onto the ISEB microcontrolle...

Страница 5: ...hown in Figure 7 When the ISEB is connected to the PC the correct firmware is selected automatically and the downloader is fully configured but you must follow these steps to flash the firmware 1 Click Start in the ARMWSD box see Figure 7 to initiate the flashing process and press the two buttons shown in Figure 10 on the ISEB in the following order to flash the firmware a Press and hold down SW1 ...

Страница 6: ...etup exe file located in the EVAL ADXRS290 M GUI Installer folder Complete the following steps to install the evaluation software 1 Choose the destination directory The installer auto populates the names of the directories in which to store the software GUI and required National Instruments products see Figure 11 You can change these directories however most installations can proceed with the defa...

Страница 7: ...PER SETTINGS Set the jumper settings and link options on the evaluation board for the required operating modes before powering on the board The functions of the jumpers are described in Table 1 Table 1 Jumper Settings Jumper Description P1 Interface to connect the main board to the satellite board JP1 Jumper used to select different functions of the SYNC ASEL pin Pin 11 of ADXRS290 Connect to GND ...

Страница 8: ... the COM port See the PC Device Manager area under the Ports COM LPT submenu to determine which COM port is assigned to the Analog Devices inertial sensor evaluation system see Figure 6 Select this COM port from the drop down menu and click Connect to begin using the GUI After the COM port is connected the full functionality of the software evaluation GUI is available for use The following section...

Страница 9: ... then displayed in the Operation Conditions box To write a value to a register select the register from the Write Target Register menu within the Register Write box and select the D7 through D0 indicators to set the value If an indicator is lit the value written to that bit is a Logic 1 whereas an unlit indicator indicates a Logic 0 When the register is configured correctly click the Write Target ...

Страница 10: ...s which is useful for recording the response of the device even during long term events The first text file is named and located by you the other 10 text files are named based on the first text file and are located in the same folder For example if you name the first text file ADXRS290Test txt in the pop up dialog box and save it on your desktop the other 10 text files which are named ADXRS290Test...

Страница 11: ...configuration click the Calculate RMS Noise Noise Density button to begin noise calculation To prevent software conflicts many of the options and tabs are grayed out or disappear until the system finishes the noise calculation Ensure that the evaluation board is in a vibration free environment when you test the noise performance Any vibration on the evaluation board may cause the fault noise resul...

Страница 12: ...s of the gyroscope and power consumption of the ADXRS290 at the same time see Figure 18 Click the Start Acquisition button to begin the real time measurement of the two axes of the gyroscope and power consumption To prevent software conflicts many of the option tabs are grayed out or disappear until you click the Stop Acquisition button The gyroscope output data and ADXRS290 power consumption data...

Страница 13: ... 1 Hz and an effective bandwidth of 0 5 Hz Low data rates are desirable for temperature testing because offset stability vs temperature is a predominantly dc behavior The operation for View Measurement View Save Measurement and Stop Measurement is the same as described in the Real Time Data Tab section To avoid measurement error use the following precautions Keep the temperature sweep ramp rate lo...

Страница 14: ...er party for any reason Upon discontinuation of use of the Evaluation Board or termination of this Agreement Customer agrees to promptly return the Evaluation Board to ADI ADDITIONAL RESTRICTIONS Customer may not disassemble decompile or reverse engineer chips on the Evaluation Board Customer shall inform ADI of any occurred damages or any modifications or alterations it makes to the Evaluation Bo...

Отзывы: