DESCRIPTION OF MAIN WINDOW

 

When the software is launched, the main software window 
opens (see Figure 14). 
The evaluation software panel as shown in Figure 14 has the 
following features: 

 

Menu bar 

 

Control buttons 

 

FPGA configuration options 

 

Data capture display 

 

AC/DC analysis 

Menu Bar  

The menu bar, labeled 1 in Figure 14, consists of the 

File

,

 Edit

and 

Help

 menus. 

File Menu 

 

Save Captured Data.

 Saves captured data in .csv format for 

future analysis. 

 

Load Captured Data. 

Loads previously captured data in 

comma separated values (.csv) format for analysis. 

 

Take Screenshot

. Saves screenshot of window as a .jpeg file. 

 

Print Screenshot

. Sends screenshot of window to the 

default printer. 

 

Exit. 

Exits the program. 

Edit Menu 

 

Reinitialize to default

. Places the evaluation board in a 

known default state. 

Help Menu 

 

Analog Devices Website. 

Opens the Analog Devices 

website in the default browser. 

 

Context Help. 

Turns on context sensitive help. 

 

About. 

Provides evaluation kit information. 

Control Buttons, Drop-Down Boxes, and Indicators 

The evaluation software includes the following control buttons, 
drop-down boxes, and indicators. 

 

The

 Eval Board Connected

 box (labeled 2 in Figure 14) 

indicates whether the 

EVAL-AD7405FMCZ

 board has been 

detected.

 

 

The

 FPGA Settings

 section (labeled 6 in Figure 14) specifies 

the MCLK frequency used for the serial interface and the 
decimation ratio used by the FPGA to filter the data.

 

 

The

 Samples

 drop-down box (labeled 4 in Figure 14) 

allows selecting the number of samples to be captured in a 
single acquisition.

 

 

Clicking

 Single Capture

 (see label 5 in Figure 14) initiates 

the sampling and readback of the number of measurements 
defined in the 

Samples

 box. 

 

Clicking 

Continuous Capture 

(see label 5 in Figure 14) 

performs a continuous capture from the ADC. Clicking 

Continuous Capture

 a second time to stop sampling. 

Window Tabs 

There are five tabs available in the tabs area (labeled 3 in Figure 14) 
of the main window: 

Configure

Waveform

Histogram

FFT

, and 

Summary

. These tabs are used to switch among device 

configuration, waveform analysis, histogram analysis, FFT 
analysis, and a summary of the last capture. Each tab is described 
in more detail in the Generating a Waveform Analysis Report; 
Generating a Histogram of the ADC Code Distribution; 
Generating a Fast Fourier Transform of AC Characteristics; and 
Generating a Summary of the Waveform, Histogram, and Fast 
Fourier Transform sections.  

Graph Tools 

Graph tools are provided within each tab to allow you to control 
the cursor, zooming, and panning (see Figure 15) within the 
graphs displayed.  

 

Figure 15. Graph Tools 

 

 

1

2

3

1. USED FOR CONTROLLING THE
    CURSOR, IF PRESENT.
2. USED FOR ZOOMING IN AND OUT.
3. USED FOR PANNING.

12304-

015

Rev. 0 | Page 14 of 20 

Содержание EVAL-AD7405FMCZ

Страница 1: ...D DESCRIPTION The EVAL AD7405FMCZ is a full featured evaluation board designed to allow the user to easily evaluate all features of the AD7405 isolated analog to digital converter ADC The evaluation board can be controlled by the EVAL SDP CH1Z via the FMCZ connector J9 The SDP H1 board EVAL SDP CH1Z allows the evaluation board to be controlled through a USB port of a PC using the evaluation board ...

Страница 2: ...ut Signals 7 Link Configuration Options 9 Setup Conditions 9 Evaluation Board Circuitry 10 Sockets Connectors 10 Test Points 10 Basic Hardware Setup 11 Evaluation Board Software 12 Starting the Software 12 Description of Main Window 14 Generating a Waveform Analysis Report 15 Generating a Histogram of the ADC Code Distribution 16 Generating a Fast Fourier Transform of AC Characteristics 17 Generat...

Страница 3: ... evaluation board as shown in Figure 2 4 Connect the EVAL SDP CH1Z board to the PC via the USB cable For Windows XP you may need to search for the EVAL SDP CH1Z drivers Choose to automatically search for the drivers for the EVAL SDP CH1Z board if prompted by the operating system 5 Power up the EVAL SDP CH1Z by inserting the 12 V dc barrel jack included with EVAL SDP CH1Z into the barrel connector ...

Страница 4: ...he CD 2 Double click the setup exe file to begin the installation By default the software is saved to the following location C Program Files Analog Devices AD740X 3 A dialog box appears asking for permission to allow the program to make changes to your computer Click Yes to begin the installation process see Figure 3 Figure 3 Evaluation Software Installation User Account Control 4 Select the locat...

Страница 5: ...begin the driver installation process see Figure 7 Figure 7 EVAL SDP CH1Z Drivers Installation Setup Wizard 2 Select the location to install the drivers and then click Install see Figure 8 Figure 8 EVAL SDP CH1Z Drivers Installation Choose Install Location 3 Click Install to proceed with the installation see Figure 9 Figure 9 EVAL SDP CH1Z Drivers Installation Windows Security 4 To complete the dr...

Страница 6: ...l connector labeled 12V_VIN on the EVAL SDP CH1Z board 4 Connect the EVAL SDP CH1Z board to the PC via the USB cable enclosed in the EVAL SDP CH1Z kit Verifying the Board Connection 1 Allow the Found New Hardware Wizard to run after the EVAL SDP CH1Z board is plugged into your PC If you are using Windows XP you may need to search for the EVAL SDP CH1Z drivers Choose to automatically search for the...

Страница 7: ...t of link options This evaluation board is designed to be supplied via the EVAL SDP CH1Z The EVAL SDP CH1Z generates 12 V and 3 3 V supply rails The 12 V supply is connected to the on board 5 V linear regulator that supplies the ADuM6000 with power The ADuM6000 then generates an isolated 5 V supply to power the VDD1 rail of the AD7405 The 3 3 V supply rail from the EVAL SDP CH1Z is used to supply ...

Страница 8: ... AD7405FMCZBlock Diagram SDP H1 BOARD XILINX SPARTAN 6 FPGA ADuM6000 12V SUPPLY ADP7104 5 0 AD7405 LOW VOLTAGE VIN VIN VDD1 VDD2 ADP2241 HIGH V GND VDD1 GND B 3 3V SUPPLY VDD2 GND B A C A HIGH VOLTAGE 12304 012 MCLK MDAT MDAT MCLK Rev 0 Page 8 of 20 ...

Страница 9: ...power supplied from the EVAL SDP CH1Z board and the analog supply rail VDD1 being supplied via the on board isoPower ADuM6000 dc to dc converter Table 2 Link Options Category Link Default Position Function Power Supplies LK1 A This link selects the AD7405 VDD1 supply source Remove LK5 if using either Position A or Position B Position A VDD1 is supplied from the ADuM6000 on board device Position B ...

Страница 10: ...nal source high voltage The default interface to this evaluation board is via the FMC connector which connects the EVAL AD7405FMCZ to the EVAL SDP CH1Z board If the EVAL AD7405FMCZ board is used in standalone mode communication is achieved via the J3 and J4 SMB jacks See Table 2 for more information about configuring the evaluation board for standalone mode TEST POINTS There are several test point...

Страница 11: ... operation ensure that the link options are in their default positions as outlined in Table 2 Ensure all links are in the appropriate position before connecting the evaluation board to the EVAL SDP CH1Z Before powering up the EVAL SDP CH1Z connect the EVAL AD7405FMCZ to FMC Connector J4 on the EVAL SDP CH1Z board After the evaluation board and the EVAL SDP CH1Z board have been connected securely a...

Страница 12: ... select Programs Analog Devices AD7405 The main window of the software then opens see Figure 14 2 If the EVAL AD7405FMCZ is not connected to the USB port via the EVAL SDP CH1Z when the software is launched a connectivity error displays see Figure 13 Connect the evaluation board to the USB port of the PC wait a few seconds click Rescan and follow the instructions Figure 13 Connectivity Error Alert ...

Страница 13: ...EVAL AD7405FMCZ User Guide UG 690 Figure 14 Evaluation Software Main Window 1 2 3 4 6 5 12304 014 Rev 0 Page 13 of 20 ...

Страница 14: ...ettings section labeled 6 in Figure 14 specifies the MCLK frequency used for the serial interface and the decimation ratio used by the FPGA to filter the data The Samples drop down box labeled 4 in Figure 14 allows selecting the number of samples to be captured in a single acquisition Clicking Single Capture see label 5 in Figure 14 initiates the sampling and readback of the number of measurements...

Страница 15: ...the resulting waveform Graph controls labeled 2 in Figure 16 are located above the graph and may be used pan and zoom into particular areas of the graph see the Graph Tools section and Figure 15 for more information The Waveform Analysis area labeled 3 in Figure 16 shows statistics pertaining to the captured waveform such as maximum minimum and mean amplitudes and signal frequency Figure 16 Wavefo...

Страница 16: ... quality signal source to the VIN input on the board 2 Select the Histogram tab in the evaluation software main window 3 Click the Single Capture or Continuous Capture button labeled 1 in Figure 17 DC Input The histogram is more commonly used for dc testing To perform a histogram test of dc input 1 Select the Histogram tab in the evaluation software main window 2 Click Single Capture or Continuous...

Страница 17: ...ss filter based on the sinusoidal signal applied 2 Click the FFT tab from the main window 3 Click Single Capture or Continuous Capture As in the histogram test raw data is then captured and passed to the PC which performs the FFT and displays the resulting SNR THD and SINAD Figure 18 displays the spectral analysis results of the captured data The plot is the FFT image of the raw data The FFT Analy...

Страница 18: ...ure 19 shows the Summary tab This tab captures and displays all of the information in one window with a synopsis of the information including key performance parameters such as SNR and THD see the SNR and THD boxes labeled 1 and 2 respectively in Figure 19 Figure 19 Summary Tab 1 2 12304 019 Rev 0 Page 18 of 20 ...

Страница 19: ...location Screenshots are saved in jpeg format and can be viewed with any picture viewer editor Figure 21 Dialog Box for Saving a Screenshot PRINT SCREENSHOT To print a screenshot from the File menu select Print Screenshot The screenshot is sent to the default printer No dialog will appear when printing a screenshot OPENING FILES Loading Captured Data The software can load previously captured data ...

Страница 20: ...valuationBoard or termination of this Agreement Customer agrees to promptly return the Evaluation Board to ADI ADDITIONAL RESTRICTIONS Customer may not disassemble decompile or reverse engineer chips on the Evaluation Board Customer shall inform ADI of any occurred damages or any modifications or alterations it makes to the Evaluation Board including but not limited to soldering or any other activ...