ADT7476
Rev. B | Page 4 of 72
SPECIFICATIONS
T
A
= T
MIN
to T
MAX
, V
CC
= V
MIN
to V
MAX
, unless otherwise noted.
Table 1.
Parameter Min
Typ
Max
Unit
Test
Conditions/Comments
POWER SUPPLY
Supply Voltage
3.0
3.3
3.6
V
Supply Current, I
CC
1.5
3
mA
Interface inactive, ADC active
TEMPERATURE-TO-DIGITAL CONVERTER
Local Sensor Accuracy
±0.5
±1.5
°C
0°C ≤ T
A
≤ 85°C
±2.5
°C
–40°C ≤ T
A
≤ 125°C
Resolution
0.25
°C
Remote Diode Sensor Accuracy
±0.5
±1.5
°C
0°C ≤ T
A
≤ 85°C
±2.5
°C
–40°C ≤ T
A
≤ 125°C
Resolution
0.25
°C
Remote Sensor Source Current
180
μA
High level
11
μΑ
Low level
ANALOG-TO-DIGITAL CONVERTER
(INCLUDING MUX AND ATTENUATORS)
Total Unadjusted Error (TUE)
±2
%
For 12 V channel
±1.5
%
For all other channels
Differential Nonlinearity (DNL)
±1
LSB
8 bits
Power Supply Sensitivity
±0.1
%/V
Conversion Time (Voltage Input)
11
ms
Averaging enabled
Conversion Time (Local Temperature)
12
ms
Averaging enabled
Conversion Time (Remote Temperature)
38
ms
Averaging enabled
Total Monitoring Cycle Time
145
ms
Averaging enabled
19
ms
Averaging disabled
Input Resistance
70
120
kΩ
For V
CCP
channel
70
114
kΩ
For all other channels
FAN RPM-TO-DIGITAL CONVERTER
Accuracy
±6
%
0°C ≤ T
A
≤ 70°C
±10
%
−40°C ≤ T
A
≤ +120°C
Full-Scale Count
65,535
Nominal Input RPM
109
RPM
Fan count = 0xBFFF
329
RPM
Fan count = 0x3FFF
5000
RPM
Fan count = 0x0438
10,000
RPM
Fan count = 0x021C
OPEN-DRAIN DIGITAL OUTPUTS, PWM1 TO PWM3, XTO
Current Sink, I
OL
8.0
mA
Output Low Voltage, V
OL
0.4
V
I
OUT
= −8.0 mA
High Level Output Current, I
OH
0.1
20
μA
V
OUT
= V
CC
OPEN-DRAIN SERIAL DATA BUS OUTPUT (SDA)
Output Low Voltage, V
OL
0.4
V
I
OUT
= −4.0 mA
High Level Output Current, I
OH
0.1
1.0
μA
V
OUT
= V
CC
SMBUS DIGITAL INPUTS (SCL, SDA)
Input High Voltage, V
IH
2.0
V
Input Low Voltage, V
IL
0.4
V
Hysteresis
500
mV
DIGITAL INPUT LOGIC LEVELS (TACH INPUTS)
Input High Voltage, V
IH
2.0
V
3.6
V
Maximum input voltage