Preliminary Technical
Data
Rev. PrA | Page 73 of 82
ADI_ADRV9025_CLGC_CAP_SAVE_FUNC_ERR
CLGC capture did not complete
successfully. This error occurs if
the correlator hardware in the
device was not successfully
stopped or the ORx channel was
not successfully released after a
CLGC capture.
•
Disable CLGC. Verify that other cals
are still running.
•
If other cals are still running, then it
might require a full firmware reset.
ADI_ADRV9025_CLGC_CAP_DONE_ERR
CLGC capture aborted due to
error
•
This could be due to other errors in
the system. Examine that other parts
of the system are operating correctly.
•
Might require a full firmware reset if
CLGC gets stuck in this state.