INSERTION LOSS OF THE THROUGH CALIBRATION PATH
To calibrate board trace losses, a through calibration path is
provided between the J6 and J5 connectors. J6 and J5 must be
populated with 2.92 mm (K) connectors to use the through
calibration path. Figure 3 shows the insertion loss, input return
loss, and output return loss of the through calibration path.
Table 2 lists the insertion loss of the through calibration path vs.
frequency.
0
–30
IN
S
E
R
TION
LOS
S
, IN
P
U
T R
E
TU
R
N
LOS
S
, A
N
D
O
UT
P
UT
RE
T
URN L
O
S
S
(
d
B)
FREQUENCY (GHz)
4.6
6.2
6.0
5.8
5.6
5.4
5.2
5.0
4.8
–25
–20
–15
–10
–5
INSERTION LOSS
INPUT RETURN LOSS
OUTPUT RETURN LOSS
26242-
003
Figure 3. Insertion Loss, Input Return Loss, and Output Return Loss of
Through Calibration Path vs. Frequency
Table 2. Insertion Loss of Through Calibration Path
Frequency (GHz)
Insertion Loss (dB)
4.6
−0.35
4.8
−0.37
5.0
−0.37
5.2
−0.38
5.4
−0.39
5.6
−0.38
5.8
−0.38
6.0
−0.39
6.2
−0.38